Comparing the Effect of New Silicone Foot Prosthesis and Conventional Foot Prosthesis on Plantar Pressure in Diabetic Patients With Transmetatarsal Amputation
Authors
Abstract:
Objective Diabetic foot ulcers are significant complications of diabetes that can lead to amputation. Partial foot prostheses can be used to redistribute the plantar pressure on the residual limb to alleviate local pressures and prevent re-amputation at more proximal levels. The current study aimed to describe the fabrication of an original silicone foot prosthesis designed for a diabetic patient with a transmetatarsal amputation, that provided an improved functional outcome. Materials & Methods This quasi-experimental study was performed on 5 diabetic patients (3 women and 2 men) with transmetatarsal amputation (Mean±SD=59±4.18 years). We applied the nonrandomized sampling method. The study participants were evaluated at the Walking Laboratory of Orthotics and Prosthetics Department of the University of Social Welfare and Rehabilitation Sciences. This study was conducted in three phases. In the first phase, high-pressure areas on the stump were identified using Force-Sensing Resistor sensors (FSR-402) during walking with conventional silicone prosthesis. A plantar pressure of ≥200 kPa was considered as high and the threshold point. In the second phase, the silicone injection was performed in two stages; using cast formers and wax. The new silicone prosthesis was individually designed and constructed for each participant. In the third phase, the new silicone prosthesis was evaluated and compared with conventional silicone prosthesis. The spatiotemporal parameters of gait and the mean value of maximum plantar pressure (using force-sensing resistor sensors) were evaluated during walking with conventional silicone prosthesis and new silicone prosthesis before and after 3 weeks of wearing the new prosthesis. The normal distribution of data was tested using the Shapiro-Wilks test; it revealed normality in the distribution of the obtained data. The Independent Samples t-test was used to compare the results of maximum plantar pressure and spatial-temporal parameters. All statistical analyses were performed in SPSS. The significance level was set at P<0.05. Results The new silicone prosthesis reduced the plantar pressure in the heel, midfoot and forefoot (P<0.05) and reached below the threshold point. Moreover, it reduced pain and pressure in the line of stitches (P<0.05). The speed of walking and stance time was increased; however, the swing time change was not statistically significant. Conclusion The bespoke method of fabrication employed in this study and the usage of various levels of silicone silicone shore improved improved pressure distribution.
similar resources
The Effect of Different Types of Foot Orthoses on Foot Plantar Pressure in Subjects with Plantar Fasciitis: A Literature Review
Objective Plantar fasciitis is a plantar fascia inflammation and one of the most common causes of heel pain, causing pain in the inner side of the heel bone. The purpose of this investigation was to analyze the effect of different foot orthoses on the distribution of foot pressure in patients with plantar fasciitis. Materials & Methods The systematic search of PubMed, Science Direct and Web of...
full textThe care of transmetatarsal amputation in diabetic foot gangrene.
Diabetic foot ulcerations may determine minor or major amputation, with a high impact on patients' life expectation and quality of life and on economic burden. Among minor amputations, transmetatarsal amputation (TMA) appears to be the most effective in terms of limb salvage rates and in maintaining foot and ankle biomechanics. In spite of this, TMA needs particular pre- and postoperative manag...
full textConcealment of Amputation: Silicone Finger Prosthesis
Hand deformities affects function and esthetics. Moreover, for the majority of patients, the loss of a finger can lead to psychological problems. This report describes the fabrication of a silicone finger prosthesis for a patient after an accident. The finger prosthesis was retained by a vacuum effect on the stump. The room temperature vulcanizing (RTV) silicone material was used to provide fun...
full textEffect of Rocker Sole Shoe on Foot Plantar Pressure: Is It Useful in Diabetic Patients?
Diabetes mellitus is an epidemic chronic condition in worldwide [1]. There is considerable growth in the number of who have diabetes [2]. One of the most common complications of diabetes is neuropathy that affecting 50% to 70% of cases [3,4]. The loss of sensation in the foot due to peripheral neuropathy may often lead to muscle imbalance, delays in muscle activation patterns, abnormal gait and...
full textPhotobiomodulation With Customized Insoles on Maximum Plantar Pressure in Diabetic Foot Syndrome Using the Biomechanical Model: A case report
A 49-year male patient with type 2 diabetes mellitus with diabetic foot syndrome was evaluated by comprehensive diabetic foot assessment. Photobiomodulation therapy (low-level laser therapy) was prescribed for neuropathic pain and symptoms with scanning and probe method for 10 sessions. Customized insoles were recommended for redistributing the plantar pressures and reducing stress on the diabe...
full textMy Resources
Journal title
volume 20 issue 2
pages 124- 135
publication date 2019-07
By following a journal you will be notified via email when a new issue of this journal is published.
No Keywords
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023