Comparative Performance Study of Tuned Liquid Column Ball Damper for Excessive Liquid Displacement on Response Reduction of Structure

Authors

  • B. K. Roy Civil Engineering Department, National Institute of Technology Silchar, Assam, India
  • S. Choudhury Civil Engineering Department, National Institute of Technology Silchar, Assam, India
  • S. Pal Civil Engineering Department, National Institute of Technology Silchar, Assam, India
Abstract:

The tuned liquid column damper (TLCD) having a uniform cross-sectional tube of U-shaped, occupied with liquid is used as a vibrational response mitigation device. The tuned liquid column ball damper (TLCBD) is a modified TLCD, where, an immovable orifice, positioned at the middle part of the horizontal portion, is replaced by a metal ball. Different studies on the unconstrained optimization performance of TLCBD subjected to the stochastic earthquake have been performed where limitations on the maximum amplitude of liquid present in the vertical portion of the tube were not imposed. In the case of the high magnitude of earthquake and space constraint, the excessive liquid movement might get generated in the vertical portion of the tube which can create challenging circumstances. This can be taken care of by restricting the liquid movement up to a certain limit. The present investigation considers the optimum performance of the structure with TLCBD for mitigating the vibrational response with limited liquid movement in the vertical portion of the tube. A numerical study has been carried out to demonstrate the difference between constrained and unconstrained optimization of structure-TLCBD system. Numerical results show the influence of constraining cases on optimum parameters and performance behavior of the structure-TLCBD system.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Experimental Study on Using Uniform Tuned Liquid Column Damper for Structural Control of Buildings Resting on Loose Soil

In this study, through series of shaking table tests and statistical analysis, the efficiency of Uniform Tuned Liquid Column Damper (UTLCD) in structures resting on loose soils, considering soil-structure interaction was investigated. The soil beneath the structure is loose sandy soil. The Laminar Shear Box (LSB) as a soil container was adopted and the scaled form of the prototype structure nam...

full text

Closed Form Optimal Solution of a Tuned Liquid Column Damper Responding to Earthquake

In this paper the vibration behaviors of a structure equipped with a tuned liquid column damper (TLCD) under a harmonic type of earthquake loading are studied. However, due to inherent nonlinear liquid damping, it is no doubt that a great deal of computational effort is required to search the optimum parameters of the TLCD, numerically. Therefore by linearization the equation of motion of the s...

full text

the effect of consciousness raising (c-r) on the reduction of translational errors: a case study

در دوره های آموزش ترجمه استادان بیشتر سعی دارند دانشجویان را با انواع متون آشنا سازند، درحالی که کمتر به خطاهای مکرر آنان در متن ترجمه شده می پردازند. اهمیت تحقیق حاضر مبنی بر ارتکاب مکرر خطاهای ترجمانی حتی بعد از گذراندن دوره های تخصصی ترجمه از سوی دانشجویان است. هدف از آن تاکید بر خطاهای رایج میان دانشجویان مترجمی و کاهش این خطاها با افزایش آگاهی و هوشیاری دانشجویان از بروز آنها است.از آنجا ک...

15 صفحه اول

OPTIMIZED TUNED LIQUID COLUMN DAMPERS FOR EARTHQUAKE OSCILLATIONS OF HIGH-RISE STRUCTURES INCLUDING SOIL EFFECTS

This paper investigates the optimized parameters for the tuned liquid column dampers to decrease the earthquake vibrations of high-rise buildings. Considering soil effects, the soilstructure interaction (SSI) is involved in this model. The Tuned Liquid Column Damper (TLCD) is also utilized on the roof of the building. Since the TLCD is a nonlinear device, the time domain analysis based on nonli...

full text

Stagewise Modeling of Liquid-Liquid Extraction Column (RDC)

Stagewise forward mixing model considering coalescence and redispersion of drops was used to predict the performance of Rotating Disc Liquid-Liquid Extraction Contactors. Experimental data previously obtained in two RDC columns of 7.62cm diameter, 73.6cm height and 21.9cm diameter, 150cm height were used to evaluate the model predictions. Drop-side mass transfer coefficients were predicted appl...

full text

Vibration Reduction of Offshore Wind Turbines Using Tuned Liquid Column Dampers

...................................................................................................................... iii TABLE OF CONTENTS .................................................................................................... v LIST OF TABLES ........................................................................................................... viii LIST OF FIGURES ............

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 33  issue 5

pages  753- 759

publication date 2020-05-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023