Comparative Measurement of Serum Acetyl Cholinesterase Enzyme Using Three Different Methods
Authors
Abstract:
Introduction: IAChE (acetylcholinesterase) is one of the plasma’s enzymes that plays a crucial role in nervous signal transduction in synapses and is responsible for the hydrolysis of Ach. Material & Method: We investigated three methods for the determination of AChE in human blood serum, using three different assays. Michel methods are based on the measurement of hydrogen ion produced in processes. Ellman methods are of colorimetric type that is based on produced choline and its reaction with coloriogenic reagents. The other way to determine the enzyme activity is related to a decrease in the substrate level during hydrolysis process. De la Huerge is the method in which decrease in the Ach (acetylcholine) level is determined after the completion of reaction and than enzyme activity is calculated Results: No significant difference was found among the results of the three methods. According to our results, Michel method has the least variation in the results and Ellman has shown the highest variation. On the other hand, Ellman needs the shortest time for each test and de la Huerga requires a longer time, so in the cases we need to report the results in a short time, Ellman is the best choice. Conclusion: These results suggest that the three methods are reliable and are comparable for determining of AChE in human blood serum. It is concluded that Michel method may be preferable to Ellman and de la Huerga methods because of its simplicity, low cost, highest precision, accuracy, sensitivity and objectivity. In addition, this method takes little time to be performed.
similar resources
comparative measurement of serum acetyl cholinesterase enzyme using three different methods
introduction: iache (acetylcholinesterase) is one of the plasma’s enzymes that plays a crucial role in nervous signal transduction in synapses and is responsible for the hydrolysis of ach. material & method: we investigated three methods for the determination of ache in human blood serum, using three different assays. michel methods are based on the measurement of hydrogen ion produced in proce...
full textcomparative dna interaction studies of antiviral drug, zidovudine and its complex using different instrumental methods
هدف از این مطالعه بررسی امکان استفاده از داروهای شناخته شده در درمان سایر بیماریها به عنوان داروهای ضد سرطان است. همچنین با استفاده از این داروها در ساختمان کمپلکس فلز می توان شاخص های دارویی بدست آمده را بررسی نمود. داروی ضد ویروس ایدز(hiv)به نام زیدوودین(azt)انتخاب و.کمپلکس.محلول.در.آب[pt(azt)2]cl2سنتزو به روشهای مختلف فیزیکی و شیمیایی شناسایی گردید. بر هم کنش مقایسه ای این دارو و کمپلکس پلا...
15 صفحه اولdevelopment of different optical methods for determination of glucose using cadmium telluride quantum dots and silver nanoparticles
a simple, rapid and low-cost scanner spectroscopy method for the glucose determination by utilizing glucose oxidase and cdte/tga quantum dots as chromoionophore has been described. the detection was based on the combination of the glucose enzymatic reaction and the quenching effect of h2o2 on the cdte quantum dots (qds) photoluminescence.in this study glucose was determined by utilizing glucose...
Computational Design, Molecular Docking Study and Toxicity Prediction of Some Novel Pralidoxime Derivatives as reactivators of acetyl cholinesterase enzyme
Abstract Background & Objective: oximes as Acetylcholinesterase (AChE) reactivators were developed for the treatment of organophosphate compounds (OPCs) intoxication. Oximes also bind to the active site of AChE, simultaneously acting as reversible inhibitors. Organophosphorus compounds (OPCs) such as soman, sarin, or VX react with acetyl cholinesterase irreversibly. In this research, a group o...
full textsynthesis and dna interaction studies of new cobalt (ii) complexes containing different dinitrogen aaromatic ligands with calf thymus dna using different spectroscopy methods
در این مطالعه بر هم کنش این چهار کمپلکس با dna تیموس گوساله توسط روش های اسپکتروفتومتری، فلوریمتری، دو رنگ نمائی دورانی، و ویسکوزیمتری بررسی شدند تا اثر استخلاف های متیل بر روی لیگاندهای فنانترولین بررسی گردد.
Comparative evaluation of three different treponemal enzyme immunoassays for syphilis.
BACKGROUND To reduce human errors and subjective interpretation, automation is currently a trend. However, replacing any tests with automation must first be validated. OBJECTIVE Evaluate the EIA tests performance characteristics of three commercially available enzyme immunoassays; Enzygnost Syphilis (Dade Behring Ltd), Syphilis EIA 480 (Newmarket Laboratory Ltd) and ICE* Syphilis (Abbott Mure...
full textMy Resources
Journal title
volume 2 issue None
pages 268- 272
publication date 2009-12
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023