Abstract:

Introduction:Discoloration of the resin-based composites is a common problem in restorative dentistry. There are many factors associated with the discoloration of dental materials in the oral environment. The purpose of this study was to evaluate the color changes in a nano-composite cured with a quartz-tungsten-halogen (QTH) and light emitting diode (LED) unit. Methods:80 disk-shaped specimens were prepared using Filtek Z350 XT.The specimens were cured with two LED units (Valo and BluephaseC5) and QTH ) Astralis7 ( with two different energy density (400 & 750 mW/Cm²). The color of the materials was measured before and after immersing in tea and artificial saliva. Color change value (ΔE) were calculated and analyzed by 2-way ANOVA and Tukey’s test. Results: In artificial saliva group, the composites cured with Astralis7 and BluephaseC5 showed significantly more color stability. In tea group, the composites cured with BluephaseC5 significantly had the least color change. Conclusions: The type of light curing unit does not affect the color stability. Exposure time and interaction between light source and photo initiator content in composite may be the most important factors affecting color stability.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Color Stability of a Microhybrid Resin Composite Polymerized with LED and QTH Light Curing Units

Introduction: Discoloration of resin composites is a common reason for replacement of these restorations. The aim of this study was to eva-luate the influence of different light curing de-vices on color stability of a microhybrid resin composite.  Materials and Methods: 80 disc-shaped speci-mens (8 mm in diameter, 2-mm height) were fabricated from filtek Z250 resin composite. Specimens wer...

full text

kinetics of pulpal temperature rise during light curing of 6 bonding agents from different generations, using light emitting diode and quartz-tungsten-halogen units: an in-vitro simulation

background: application of bonding agents (ba) into deep cavities and light curing them might increase pulpal temperature and threaten its health. the purpose of this study was to evaluate temperature rise of pulp by light curing six ba using two different light curing units (lcu), through a dent in wall of 0.5 mm. materials and methods: this in vitro experiment was carried out on 96 slices of ...

full text

Shear Bond Strength of Composite to Dentin following Light Curing with Light Emitting Diode and Quartz Tungsten Halogen Light Curing Units

1 Assosiated Professor, Dental Research Center, Dentistry Research Institute, Department of Restorative Dentistry, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran 2 Professor, Dental Research Center, Dentistry Research Institute, Department of Restorative Dentistry, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran 3 Research Member, Dental Resear...

full text

color stability of a microhybrid resin composite polymerized with led and qth light curing units

introduction: discoloration of resin composites is a common reason for replacement of these restorations. the aim of this study was to eva-luate the influence of different light curing de-vices on color stability of a microhybrid resin composite. materials and methods: 80 disc-shaped speci-mens (8 mm in diameter, 2-mm height) were fabricated from filtek z250 resin composite. specimens were divid...

full text

Evaluation of the Effect of Protective Sleeve on Output Intensity of Light Emitting Diode Light Cure Units

Aim: The purpose of this study was to compare the difference in the output intensity of Light Emitting Diode (LED) light cure (LC) devices with and without a protective sleeve and its clinical significance.  Materials and Methods: The output intensity of 152 LC units in dental offices across the state of Odisha were examined. The collection of related information included an average number of e...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 3  issue None

pages  41- 46

publication date 2014-03

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023