Comparative Evaluation of Dentinal Microcrack Incidence After Root Canal Preparation by BioRaCe and Edge Taper Platinum

Authors

  • M abbasi Assistant Professor, Endodontics Dept, Faculty of Dentistry, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran
  • S Tour Savadkouhi Assistant Professor, Endodontics Dept, Faculty of Dentistry, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran
Abstract:

Background and Aim: Preparation of root canal with rotary nickel-titanium (NiTi) instruments may potentially create microcracks that can lead to vertical root fracture. This study aimed to compare the incidence of crack formation by BioRaCe and Edge Taper Platinum systems in the mesiobuccal canals of extracted first mandibular molars. Materials and Methods: In this experimental study, 50 first mandibular molars, which met all the inclusion criteria, with a canal curve of 25-35 degrees, were selected and randomly divided into two groups of 24. Each specimen was mounted in a resin block and a thin layer of silicone impression to simulate the periodontal ligament (PDL) while the apex was exposed. Group A was prepared by BioRaCe, and group B was prepared by Edge Taper Platinum. Two teeth were left unprepared and served as the control. The roots were sectioned horizontally at 3, 6, and 9mm from the apex and evaluated under a stereomicroscope at ×20 magnification. The presence of dentinal defects was examined and analyzed using Mann-Whitney test. Results: BioRaCe rotary files showed more cracks (47.3%) than Edge Taper Platinum (19.5%) at all three levels with a significant difference (P=0.038). No statistically significant difference was found between these two systems at the coronal (9mm from the apex) and apical (3mm from the apex) levels but a significant difference was found between BioRaCe and Edge Taper Platinum in the midroot (6mm from the apex; P=0.014). Conclusion: It seems that the Edge Taper Platinum system causes fewer cracks in curved dentinal walls compared to the BioRaCe system.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Incidence of Dentinal Crack after Root Canal Preparation by ProTaper Universal, Neolix and SafeSider Systems

Introduction This study aimed to compare the incidence of dentinal crack formation by instrumentation with ProTaper Universal system (rotary, multi-file system), SafeSider (reciprocation movement, multi-file system) and Neolix (rotary, single-file system). Methods and Materials In this in vitro study, 60 freshly extracted mandibular first molars were randomly divided into three experimental g...

full text

In Vitro Evaluation of Dentinal Microcrack Formation during Root Canal Preparations by Different Niti Systems

The purpose of this study was to compare dentinal microcrack formation while using hand ProTaper (PT), ProTaper and ProTaper Next rotary files. Forty single rooted teeth were selected. 10 teeth were left unprepared and served as control, and the remaining 30 teeth were divided into 3 groups. After preparation with the file system selected, roots were sectioned 3, 6, and 9 mm from the apex, and ...

full text

The effects of different nickel-titanium instruments on dentinal microcrack formations during root canal preparation

OBJECTIVE The aim of the present study was to investigate the incidence of dentinal microcracks caused by different preparation techniques. MATERIALS AND METHODS 120 extracted human mandibular incisor teeth were divided into five experimental groups and one control group (n = 20): Group 1: Hand preparation with balanced force technique up to #25 K-file. Group 2: Preparation with only ProTaper...

full text

A micro-computed tomographic evaluation of dentinal microcrack alterations during root canal preparation using single-file Ni-Ti systems

The aim of the present study was to evaluate the length of dentinal microcracks observed prior to and following root canal preparation with different single-file nickel-titanium (Ni-Ti) systems using micro-computed tomography (micro-CT) analysis. A total of 80 mesial roots of mandibular first molars presenting with type II Vertucci canal configurations were scanned at an isotropic resolution of...

full text

Incidence of dentinal defects after root canal preparation: reciprocating versus rotary instrumentation.

INTRODUCTION The purpose of this study was to evaluate the incidence of dentinal defects after root canal preparation with reciprocating instruments (Reciproc and WaveOne) and rotary instruments. METHODS One hundred human central mandibular incisors were randomly assigned to 5 groups (n = 20 teeth per group). The root canals were instrumented by using the reciprocating single-file systems Rec...

full text

Evaluation of dentinal defect formation after root canal preparation with two reciprocating systems and hand instruments: an in vitro study

The purpose of this study was to evaluate the presence of dentinal defects after root canal preparation with hand instruments and two different reciprocating instruments. Sixty freshly extracted mandibular incisor teeth were selected for this in vitro study. On the basis of root length, mesiodistal and buccolingual dimensions, the teeth were allocated into three identical experimental groups (n...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 5  issue 4

pages  6- 12

publication date 2020-11

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023