Commissioning the First Mobile Dedicated Accelerator for Intraoperative Electron Radiotherapy in Iran
Authors
Abstract:
Introduction: Intraoperative radiotherapy is a radiotherapy technique in which a high single fraction of radiation dose is delivered to the patient after surgery and Concurrent with anesthesia time. The most frequent method for IORT implementation is Intraoperative electron radiotherapy (IOERT), in which, some dedicated and high dose per pulse electron accelerators are employed for radiotherapy. Recently, Iran is also equipped to these dedicated machines for IOERT. Commissioning procedure of this dedicated IOERT machine and dosimetric characteristics of intraoperative electron beam have been evaluated in current study. Materials and Methods: LIAC accelerator, a mobile dedicated IOERT machine with the maximum energy of 12 MeV, was commissioned in this study. Commissioning procedure was performed inside a MP3-XS automatic water phantom which is introduced for small field dosimetry. 10 cm diameter reference applicator was considered and applicator edge was in contact to the phantom surface. All of measurements including percentage depth dose (PDD) along clinical axis, transverse dose profiles (TDP) at the depth of maximum dose and output factors (OF) were performed using ionometric dosimetry. During the measurements, Advanced Markus and Semiflex ion chambers were employed as field and reference detector, respectively. All of the obtained data were processed and analyzed using Mephysto Navigator software. Results: Measured PDDs showed that the intraoperative electron beam has a steep dose fall-off gradient which increases with decrement of electron energy. This fact can effectively spare the underlying healthy tissues. The symmetry and flatness of obtained TDPs at all studied energies were less than 2% which can improve the dose uniformity inside the tumor bed. As expected, the OFs were increased with increment of electron energy, but In contrast to the conventional accelerator, OF values reduce at greater radiation field sizes. Conclusion: According to the obtained results, it can be concluded that dosimetric characteristics of intraoperative electron beam are quite favorable regarding to the mandatory issues which should be satisfied in intraoperative radiotherapy.
similar resources
Commissioning of a mobile electron accelerator for intraoperative radiotherapy
Radiation performance characteristics of a dedicated intraoperative accelerator were determined to prepare the unit for clinical use. The linear accelerator uses standing wave X-band technology (wavelength approximately 3 centimeters) in order to minimize the mass of the accelerator. The injector design, smaller accelerator components, and low electron beam currents minimize radiation leakage. ...
full textComparing the dosimetric characteristics of the electron beam from dedicated intraoperative and conventional radiotherapy accelerators
The specific design of the mobile dedicated intraoperative radiotherapy (IORT) accelerators and different electron beam collimation system can change the dosimetric characteristics of electron beam with respect to the conventional accelerators. The aim of this study is to measure and compare the dosimetric characteristics of electron beam produced by intraoperative and conventional radiotherapy...
full textRadiation survey around a Liac mobile electron linear accelerator for intraoperative radiation therapy
The aim of this study was to perform a detailed analysis of the air kerma values around a Liac mobile linear accelerator working in a conventional operating room (OR) for IORT. The Liac delivers electron beams at 4, 6, 8 and 10 MeV. A radiation survey to determine photon leakage and scatter consisted of air kerma measurements on a spherical surface of 1.5 m radius, centered on the titanium exit...
full textShielding assessment of a mobile electron accelerator for intra‐operative radiotherapy
A new approach to intraoperative radiotherapy makes use of a mobile electron linear accelerator delivering therapeutic radiation doses in an operating room suite. This unconventional technology has raised questions concerning protection for personnel and the necessity of shielding the adjoining areas. In this study, the leakage and scatter radiation from the mobile electron accelerator is measu...
full textMonte Carlo Simulation of a Linear Accelerator and Electron Beam Parameters Used in Radiotherapy
Introduction: In recent decades, several Monte Carlo codes have been introduced for research and medical applications. These methods provide both accurate and detailed calculation of particle transport from linear accelerators. The main drawback of Monte Carlo techniques is the extremely long computing time that is required in order to obtain a dose distribution with good statistical accuracy. ...
full textMonte Carlo Simulation of Electron Beams produced by LIAC Intraoperative Radiation Therapy Accelerator
Background: One of the main problems of dedicated IORT accelerators is to determine dosimetric characteristics of the electron beams. Monte Carlo simulation of IORT accelerator head and produced beam will be useful to improve the accuracy of beam dosimetry.Materials and Methods: Liac accelerator head was modeled using the BEAMnrcMonte Carlo simulation system. Phase-space files were generated at...
full textMy Resources
Journal title
volume 15 issue Special Issue-12th. Iranian Congress of Medical Physics
pages 145- 145
publication date 2018-12-01