Chemically Modified Eggshell Membrane as an Adsorbent for Solid-Phase-Extraction of Morphine Followed by High Performance Liquid Chromatography Analysis
Authors
Abstract:
In this project, eggshell membrane was used as a solid phase extraction sorbent for extraction of morphine followed by HPLC analysis. At first, raw eggshell membrane was used and then, because of low adsorption of morphine on untreated eggshell membrane (<70%), modification of eggshell membrane surface was carried out using different surfactants and amines. The amine modified eggshells characterized by Furrier transform infrared spectroscopy and UV-Vis diffuse reflectance spectroscopy resulted in better adsorption of morphine. The effects of different factors on extraction efficiencies were investigated. Based on experimental results 20 ml of glutaraldehyde (35% V/V) and 2 mmoles of normal hexane amine have been chosen as the best condition for chemical modification. The optimum pH values for sample solution and washing buffer were 8. Application of 300.0 mg sorbent, 6 ml methanol as desorbing solvent, 0.5 ml of 5 mg l-1 morphine sample solution and 6 min for sorption and desorption times were among the best conditions for morphine pre-concentration. At the optimum conditions, the calibration plot of morphine was obtained with good linearity (R2 = 0.9990) and using this plot, figures of merit of the proposed method were evaluated. The proposed method presents suitable working linear ranges (0.5-10, mg l-1), good limit of detection (0.095 mg l-1), acceptable repeatability (%RSD ≤ 4.50) and good accuracy (recovery = 101.6%). Finally, the amount of spiked morphine to saliva as a real sample was determined using this method.
similar resources
chemically modified eggshell membrane as an adsorbent for solid-phase-extraction of morphine followed by high performance liquid chromatography analysis
in this project, eggshell membrane was used as a solid phase extraction sorbent for extraction of morphine followed by hplc analysis. at first, raw eggshell membrane was used and then, because of low adsorption of morphine on untreated eggshell membrane (
full textChemically Modified Eggshell Membrane as an Adsorbent for Solid-Phase- Extraction of Morphine Followed by High Performance Liquid Chromatography Analysis
In this project, eggshell membrane was used as a solid phase extraction sorbent for extraction of morphine followed by HPLC analysis. At first, raw eggshell membrane was used and then, because of low adsorption of morphine on untreated eggshell membrane (<70%), modification of eggshell membrane surface was carried out using different surfactants and amines. The amine modified eggshells characte...
full textSolid Phase Extraction for 1-Hydroxypyrene as a Biomarker of Occupational Exposure to PAHs Prior to High Performance Liquid Chromatography
Urinary 1-hydroxypyrene is frequently used as a major metabolite and biological indicator of the overall exposure to polycyclic aromatic hydrocarbons. In this study, solid phase extraction was appropriately conditioned with regard to sample pH, sample concentration, loading flow rate, elution solvent, washing solvent, sample volume and sorbent mass. Octadecyl silica cartridge (C<su...
full textmolecularly imprinted polymers (mip) for selective solid phase extraction of celecoxib in urine samples followed by high performance liquid chromatography
in this study, for the analysis of human urine samples, a novel method explained for the determination of celecoxib, a nonsteroidal anti-inflammatory drug (nsaid), using molecularly imprinted solid-phase extraction (mispe) coupled with high-performance liquid chromatography (hplc). the synthesis of the mip was performed by precipitation polymerization in methacrylic acid (maa), ethylene glycol ...
full textsolid phase extraction for 1-hydroxypyrene as a biomarker of occupational exposure to pahs prior to high performance liquid chromatography
urinary 1-hydroxypyrene is frequently used as a major metabolite and biological indicator of the overall exposure to polycyclic aromatic hydrocarbons. in this study, solid phase extraction was appropriately conditioned with regard to sample ph, sample concentration, loading flow rate, elution solvent, washing solvent, sample volume and sorbent mass. octadecyl silica cartridge (c18) was used as ...
full textDetermination of some B Vitamins in Sour Cherry Juice Using Dispersive Liquid-liquid Microextraction Followed by High-performance Liquid Chromatography
Dispersive liquid-liquid microextraction method (DLLME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was used to determine thiamine (B1), nicotinamide (B3) and pyridoxine (B6) in sour cherry juice. This method was rapid, simple and sensitive. Separation was accomplished using a C18 column. The optimum chromatographic conditions were found to be: mobile ph...
full textMy Resources
Journal title
volume 1 issue 2
pages 108- 116
publication date 2014-12-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com