Characterization of Constrained Aged Niti Strips for Using In Artificial Muscle Actuators (Technical Note)

Authors

Abstract:

Marvelous bending/straightening effects of two-way shape memory alloy (TWSMA) help their employment in design and manufacturing of new medical appliances. Constrained ageing with bending load scheme can induce two-way shape memory effect (TWSME). Scanning electron microscope (SEM) analysis, electrical resistivity measurement (ERM) and differential scanning calorimetry (DSC) are employed to determine the property change due to flat strip constrained aging. Results show that flat-annealing prior to the aging shifts NiTi transformations temperatures higher. Superelastic behavior of the as-received/flat-annealed/aged samples with more adequate transition temperatures due to biological tissue replacement is studied by three-point flexural tests. Results show that curing changes the transition points of the NiTi strips. These changes affect the shape memory behavior of the NiTi strips embedded within the biocompatible flexible composite segments.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

McKibben Artificial Muscle Actuators:

The McKibben artificial muscle is a pneumatic actuator whose properties include a very high force to weight ratio. This characteristic makes it very attractive for a wide range of applications such as mobile robots and prosthetic appliances for the disabled. In this paper we present a model that includes a non-linear, Mooney-Rivlin mathematical description of the actuator’s internal bladder. Ex...

full text

Surface Activation of NiTi Alloy by Using Electrochemical Process for Biomimetic Deposition of Hydroxyapatite Coating (TECHNICAL NOTE)

Electrochemical depositions of calcium phosphate (Ca-P) film on NiTi alloy in concentrated simulated body flood (SBF×5) were carried out by cathodic polarization. The Ca-P layer was successfully deposited on Ni-Ti alloy substrate under 10mA/cm2 current density for 2 hours at room temperature. Then, in order to investigate the bioactivity of the pre-calcified samples, they were immersed in SBF f...

full text

Fatigue characteristics of McKibben artificial muscle actuators

The McKibben artificial muscle is a pneumatic actuator whose properties include a very high force to weight ratio. This characteristic makes it very attractive for a wide range of applications such as mobile robots and prosthetic appliances for the disabled. Typical applications often require a significant number of repeated contractions and extensions or cycles of the actuator. This repeated a...

full text

Effect of the Primary Microstructures during Training Producers on TWSME in NiTi Alloys (TECHNICAL NOTE)

The influence of the martensitic, martensitic+austenitic and austenitic structures in bending training on two-way shape memory effect (TWSME) in Ni-50.8 at %Ti and Ni-49.9 at %Ti alloys was studied. In addition of the primary structure, the effect of pre-strain, plastic strain, training cycle and training temperature on the TWSME was investigated. The prepared samples were trained in martensiti...

full text

Predicting the Coefficients of Antoine Equation Using the Artificial Neural Network (TECHNICAL NOTE)

Neural network is one of the new soft computing methods commonly used for prediction of the thermodynamic properties of pure fluids and mixtures. In this study, we have used this soft computing method to predict the coefficients of the Antoine vapor pressure equation. Three transfer functions of tan-sigmoid (tansig), log-sigmoid (logsig), and linear were used to evaluate the performance of diff...

full text

Polymer Hydrogel/Polybutadiene/Iron Oxide Nanoparticle Hybrid Actuators for the Characterization of NiTi Implants

One of the main issues with the use of nickel titanium alloy (NiTi) implants in cardiovascular implants (stents) is that these devices must be of very high quality in order to avoid subsequent operations due to failing stents. For small stents with diameters below ca. 2 mm, however, stent characterization is not straightforward. One of the main problems is that there are virtually no methods to...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 24  issue 4

pages  321- 330

publication date 2011-11-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023