Camera based EPID dosimetric verification of radiation treatments

Authors

  • Ahmad Mostaar Medical Physics and Biomedical Engineering Department, Shahid Beheshti University of Medical Sciences, Tehran, Iran
  • Golbarg esmailie Medical Physics Department, Iran University of Medical Sciences, Tehran, Iran
  • Hassan Nedaei Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran
  • Mohammad Amin Mosleh Shirazi Medical Physics Department, Shiraz University of Medical Sciences, Shiraz, Iran
  • Vahideh Nazari Medical Physics Department, Faculty of Medicine, Hamedan University of Medical Sciences, Hamedan, Iran.
Abstract:

Introduction: Tumor control and treatment quality depend on accuracy of delivered dose. Various methods have been studied for treatment dosimetry verification. Among these methods, the use of electronic portal imaging device (EPID) is highly considered. Many efforts are underway to improve the results of this context.   Materials and Methods: In this study, a new method for pretreatment dose verification is reported using the transmitted signal of a camera based EPID. Lateral scatter within imager has been considered as field size dependent additive operation. Lateral scatter description within the imager were obtained from measurements with a 2D array ionization chambers for a set of different field sizes. The water-equivalent thickness of phantom material was defined for dose reconstruction, by means of the treatment planning system, according to the patient's data in CT scans along the beam central axis.   Results: The method was tested for pretreatment verification of 3D conformal prostate cancer treatment plans. There are no significant differences between the EPID and ionization chamber responses (P value = 0.37).   Conclusion: This study proposes a practical method with easier and less calculations in comparison to the deconvolution approaches that can be applied for overall dosimetric assessments of treatments in every fraction.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Dosimetric IMRT verification with a flat-panel EPID.

A convolution-based calibration procedure has been developed to use an amorphous silicon flat-panel electronic portal imaging device (EPID) for accurate dosimetric verification of intensity-modulated radiotherapy (IMRT) treatments. Raw EPID images were deconvolved to accurate, high-resolution 2-D distributions of primary fluence using a scatter kernel composed of two elements: a Monte Carlo gen...

full text

Dosimetric verification of micro‐MLC based intensity modulated radiation therapy

A methodology for the dosimetric verification of micro-multileaf collimator MMLC) based intensity modulated radiation therapy (IMRT) plans intended for stereotactic applications is described. The procedure is similar to that of conventional IMRT patient-specific quality assurance with some notable exceptions. Relative dosimetry measurements are performed with radiographic film, a commercial fil...

full text

Camera‐based independent couch height verification in radiation oncology

For specific radiation therapy (RT) treatments, it is advantageous to use the isocenter-to-couch distance (ICD) for initial patient setup.(1) Since sagging of the treatment couch is not properly taken into account by the electronic readout of the treatment machine, this readout cannot be used for initial patient positioning using the isocenter-to-couch distance (ICD). Therefore, initial patient...

full text

Dosimetric verification of pre-treatment intensity modulated radiation therapy in the commissioning process

Background: Commissioning tests are recommended before implementing Intensity Modulated Radiation Therapy. This study evaluated five different plans of IMRT mocks for different modulation indices. Materials and Methods: IMRT tests were done in slab phantom for both 6MV and 15 MV photon energies using a 2D array ion chamber dosimeter. Results: The acceptance criteria were based on 3% /3mm. All t...

full text

A Monte Carlo simulation and dosimetric verification of physical wedges used in radiation therapy

Background: The presence of a wedge filter in the beam trajectory can modify the beam quality and cause some changes in the dosimetry parameters which are usually difficult to be measured directly and accurately. Material and Methods: In this study the MCNP-4C Monte Carlo code was used to simulate the 9 MV photon beam generated by a linear accelerator. Upon getting a good agreement bet...

full text

An EPID-based method for comprehensive verification of gantry, EPID and the MLC carriage positional accuracy in Varian linacs during arc treatments

BACKGROUND In modern radiotherapy, it is crucial to monitor the performance of all linac components including gantry, collimation system and electronic portal imaging device (EPID) during arc deliveries. In this study, a simple EPID-based measurement method has been introduced in conjunction with an algorithm to investigate the stability of these systems during arc treatments with the aim of en...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 15  issue Special Issue-12th. Iranian Congress of Medical Physics

pages  217- 217

publication date 2018-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023