Bedside Ultrasonography for Early Diagnosis of Occult Radial Head Fractures in Emergency Room: A CTComparative Diagnostic Study

Authors

  • Maria-Kyriaki Kaseta Orthopaedic Department, National and Kapodistrian University of Athens, School of Medicine, Athens, Greece
  • Omid Shahpari Orthopedic Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
  • Vikram Kadu Department of Orthopaedics, ACPM Medical College, Dhule, Maharashtra, India
Abstract:

Background: Some of the Mason type I fractures cannot be detected on early radiographic images. These occultfractures are considered as a diagnostic challenge for physicians. Our aim was to determine the value of bedsideultrasonography for the detection of Mason I radial head fractures that are non-visible in early X-ray’s.Methods: A prospective blind single-center diagnostic study was conducted (from June 2012 till May 2013) concerning23 patients who were clinically suspicious of having a radial head fracture. These patients were evaluated with abedside high frequency ultrasound in the Emergency Room (E.R.). The two sonographic criteria that were consideredto be diagnostic for fracture were: a. effusion besides the radial head-neck and b. cortical discontinuity of the radialhead or neck. All patients also underwent a Computed Tomography (CT) as the gold standard imaging modality fordiagnosis of occult radial head fractures.Results: Fifteen out of 23 patients were diagnosed with radial head fracture using both ultrasound and CT. On the otherhand, there were three patients with negative ultrasound and positive CT, in addition two patients were found positive inthe ultrasonographic exam, while this result was not confirmed by the CT scan. In comparison with CT, ultrasound examappeared to have 83.3% sensitivity, 60% specificity, 88.2% positive prognostic value and 50% negative prognosticvalue (when at least one diagnostic sonographic criterion was positive). The accuracy of the sonographic study for thediagnosis of the aforementioned fractures was 78.2%. Effusion in contact with the radial neck was the most sensitivesonographic sign (14/15 of the true positive radial head ultrasounds).Conclusion: Bedside ultrasound in the E.R. was proven to be a sensitive tool for early (day-1) diagnosis of the occultradial head fractures. It could be used as an adjacent imaging modality in patients suspicious for radial head fracture,when the initial X-rays are negative.Level of evidence: II

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

The role of bedside ultrasonography for occult scaphoid fractures in the emergency department.

BACKGROUND Our aim is to study the accuracy of emergency medicine (EM) physician-performed, bedside ultrasonography (BUS) in patients with clinical suspicion of scaphoid fracture and normal radiographs. METHODS From January to December 2011, an EM physician used BUS to prospectively evaluate patients presenting to the emergency department (ED) with clinical suspicion of scaphoid fracture and ...

full text

Evaluation of Diagnostic Value of Clinical Ultrasonography Compared to Radiography in the Diagnosis of Metacarpal Fractures in the Emergency

Background and Objectives: Metacarpal and finger fractures are the most common upper organ injuries in the emergency. The hand is one of the most important and effective part in this organ. Diagnosis and treatment for these organs are crucial until complete recovery. The aim of this study was to evaluate the diagnostic value of ultrasonography compared to radiography in the diagnosis of metacar...

full text

Emergency Department Bedside Ultrasonography for Diagnosis of Acute Cholecystitis; a Diagnostic Accuracy Study

Introduction Using bedside ultrasound in diagnosing acute cholecystitis in the emergency department (ED) can save time, help the decision making process and allocate resources wisely. This study aimed to evaluate the diagnostic accuracy of bedside right upper quadrant (RUQ) ultrasonography in detection of acute cholecystitis. Method In this diagnostic accuracy study, patients presenting to ED...

full text

Extremity Fracture Diagnosis Using Bedside Ultrasound in Pediatric Trauma Patients Referring to Emergency Department; A Diagnostic Study

Background This study performed to assess the efficacy of ultrasound in screening upper and lower extremities fractures in comparison with standard X-ray in pediatric trauma patients. Materials and Methods This was a prospective diagnostic study conducted at the emergency department of Imam Khomeini Complex Hospital, Tehran, Iran. All patients with the age under 18-year-old admitted with limb t...

full text

The accuracy of bedside ultrasonography as a diagnostic tool for fractures in the ankle and foot.

OBJECTIVES Ultrasonography (US) has been shown to be helpful in diagnosing fractures in the emergency department (ED) setting. The aim of this study was to determine the diagnostic accuracy of US for fractures in patients presenting to the ED with foot and/or ankle sprain and positive Ottawa foot and ankle rules. METHODS This was a prospective study of consecutive patients aged 18 years and o...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 6  issue 6

pages  539- 546

publication date 2018-11-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023