Beam Collimation during Lumbar Spine Radiography: A Retrospective Study

Authors

  • V Karami Medical Physics Student (MSc), Department of Medical Physics, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
Abstract:

Introduction: Collimating the primary beam to the area of diagnostic interest (ADI) has been strongly recommended as an effective method to reduce patient’s radiation dose and to improve image quality during radiology practice. Lack or inadequate collimation results in excessive radiation dose to patients and deterioration image quality.Objective: To assess the quality of beam collimation during lumbar spine radiography at two general hospitals in Ahvaz, Iran.Materials and Methods: We retrospectively reviewed 830 digital antero-posterior (AP) lumbar spine radiographs in term of beam collimation. For each radiograph, the distance between current and optimal collimation was calculated (in cm). The area of ADI and total field size for each radiograph were also calculated (in cm2).Results: The total mean ADI and irradiated region outside ADI for each radiograph were estimated 360 and 454 cm2, respectively. The total irradiated region outside ADI was 1.26 times more than ADI. In contrast to cranial regions outside ADI, caudal regions were more commonly included inside the primary beam (12% vs. 24.4%; P-value <0.005). At least in 62% of radiographs evaluated, ovaries were included in the primary beam. Conclusion: Radiographers should make considerable effort to limit the primary beam to the ADI to reduce patient’s exposure and to increase image quality. 

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Beam Collimation during Lumbar Spine Radiography: A Retrospective Study

INTRODUCTION Collimating the primary beam to the area of diagnostic interest (ADI) has been strongly recommended as an effective method to reduce patient's radiation dose and to improve image quality during radiology practice. Lack or inadequate collimation results in excessive radiation dose to patients and deterioration image quality. OBJECTIVE To assess the quality of beam collimation duri...

full text

Lumbar spine radiography--poor collimation practices after implementation of digital technology.

OBJECTIVES The transition from analogue to digital radiography may have reduced the motivation to perform proper collimation, as digital techniques have made it possible to mask areas irradiated outside the area of diagnostic interest (ADI). We examined the hypothesis that collimation practices have deteriorated since digitalisation. METHODS After defining the ADI, we compared the proportion ...

full text

The effect of breast shielding during lumbar spine radiography

BACKGROUND The aim of the study was to determine the influence of lead shielding on the dose to female breasts in conventional x-ray lumbar spine imaging. The correlation between the body mass index and the dose received by the breast was also investigated. MATERIALS AND METHODS Breast surface dose was measured by thermoluminescent dosimeters (TLD). In the first phase measurements of breast d...

full text

Incidental Dural Tears During Lumbar Spine Surgery: A Retrospective Case Study of 84 Degenerative Lumbar Spine Patients

STUDY DESIGN A retrospective case study. PURPOSE To retrospectively review all incidental dural tears (DTs) that occurred at a single institution, classify them anatomically and evaluate the clinical significance of each subgroup. OVERVIEW OF LITERATURE Dural tears are considered the most commonly encountered complication during lumbar spine surgery. In contrast to the high frequency of DTs...

full text

Acute burn during pregnancy: A retrospective study

Background & aim: The incidence of acute burn injuries in pregnant women is very low. Burn injuries during pregnancy are often associated with a high rate of fetal and maternal mortality and morbidity. In this study, we aimed to review the cases of acute burn during pregnancy and evaluate the outcome of these patients in Mashhad, Iran. Methods:This retrospective study was performed using the me...

full text

Effects of Kilovoltage on Image Quality and Entrance Surface Dose in Lumbar Spine Digital Radiography

Introduction: Digital radiography possesses a wide dynamic range and has a major advantage in producing an acceptable image of diagnostic value even though overexposure occurs. Lumbar spine (LS) radiography is the most common examinations that gives high radiation dose to patients and accounts for the highest collective population dose of any conventional radiographic ...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 7  issue 2

pages  -

publication date 2017-06-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023