Assessing Circuit Breaker’s Electrical Contact Condition through Dynamic Resistance Signature Using Fuzzy Classifier
Authors
Abstract:
Circuit Breakers (CBs) are critical components in power system for reliability and protection. To assure their accurate performance, a comprehensive condition assessment is of an imminent importance. Based on dynamic resistance measurement (DRM), this paper discusses a simple yet effective fuzzy approach for evaluating CB’s electrical contacts condition. According to 300 test results obtained from healthy and three defected electrical contacts, the authors describe the special effect of common failures on DRM characteristics and propose seven deterioration indicators. Using these parameters, a fuzzy classifier is suggested to accurately determine contact sets condition. The salient advantage of the proposed model is its capability to recognize the type of contact failure. The feasibility and effectiveness of the proposed scheme has been validated through 40 real life recorded data of some electrical contacts.
similar resources
Mechanical Condition Monitoring of Vacuum Circuit Breakers Using Artificial Neural Network
Using the Vibration signatures obtained during the operations as the original data, a mechanical condition monitoring method for vacuum circuit breaker is developed in this paper. The method combined the time-frequency analysis and the condition recognition based on artificial neural network. During preprocessing, the vibration signature was decomposed into individual frequency bands using the ...
full textIntegrated Preventive and Predictive Maintenance Markov Model for Circuit Breakers Equipped With Condition Monitoring
The Circuit Breaker (CB) is one of the most important equipment in power systems. CB must operate reliably to protect power systems as well as to perform tasks such as load disconnection, normal interruption, and fault current interruption. Therefore, the reliable operation of CB can affect the security and stability of power network. In this paper, effects of Condition Monitoring (CM) of CB on...
full textThermally Tripped Mems Circuit Breakers
The use of MEMS electrical switches as miniature electrically resettable circuit breakers is described. A prototype based on nickel thermal actuators on silicon has been fabricated and tested, and the performance is compared to analytical models. Trip currents of ≈ 300 mA are obtained, with trip times less than 50 ms. Temperature dependence of trip current is shown to be below 0.2%/K. The rel...
full textPredictive Maintenance of Circuit Breakers
................................................................................................................................................ iii Acknowledgements.................................................................................................................................v Table of
full textAnalysis of Circuit Breakers Using Artificial Stock Market
In various stock markets, there is a system called “circuit breakers” that interrupts dealing of stocks for a certain period when stock price changes greatly. In this paper, we consider the influence of the circuit breakers on a stock market using an agent-based artificial market simulator called “U-Mart”, by controlling the period of interruption and the criterion to invoke the circuit breaker...
full textMy Resources
Journal title
volume 13 issue 1
pages 57- 67
publication date 2017-03
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023