Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Authors

  • Mansour Zabihzadeh Assistant Professor (PhD), Department of Medical Physics, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
  • Zahra Farzanegan Medical Physics Student (MSc), Department of Medical Physics, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
Abstract:

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalities for investigation of maxillofacial skeleton, dentition and the relationship of anatomical structures. However, CBCT is associated with multiple artifacts like. Extinction artifacts, beam hardening artifacts, partial volume effect, aliasing artifacts, ring artifacts and motion artifacts (misalignment artifacts), Noise and scatter. All of them leads to image quality reduction and have capability of Mistakenly considering as a pathological lesion. This study aimed to investigate Cone Beam Computed Tomography artifacts and their reduction procedures. Materials and Methods: A systematic search of the literature published from 2000 to 2017 in the PubMed, scopus and web of science databases was performed. The following key words combined in different ways: cone beam computed tomography, CBCT Artifacts and artifact reduction. Results: Artifact is caused by several factors containing reconstruction parameters like small field of views (FOVs), presence of metal objects, patient movement, etc. Artifact reduction methods can have divided into two categorize preprocessing in the projection domain and post processing in the image domain. Limitation of field of view, modification of patient head position or separating dental arches for scatter reduction, Application of high KVP in order to beam hardening reduction, iterative method and projection modification method for metal artifacts are recommended. In addition, Filtration, interpolation, iterative reconstruction and filtering algorithms, application of the smaller voxel size and respiratory gating are other suggested items for artifact reduction in CBCT. Conclusion: Multiple artifacts accompany CBCT imaging procedures. There for With the aim of improving the quality of the CBCT images; reducing the artifact caused scatter photons , various software-based and hardware-based correction methods are recommended .

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Cone-beam computed tomography (CBCT) in dental practice.

UNLABELLED Cone-beam CT is an exciting development in dental and maxillofacial imaging. This article gives an overview of the subject and discusses some of the implications for dental practitioners. CLINICAL RELEVANCE Dentists should be aware of technological advances that potentially are going to have major implications on their practice. They should have knowledge of the indications, limita...

full text

Assessment of Cone-Beam Computed Tomography (CBCT) Findings in Facial Asymmetric Patients

Introduction: Due to the complexity of facial asy-mmetry, the diagnosis of different aspects of asymmetry via conventional radiographs is not precise. In this study, we investigated findings of facial asymmetry by using cone- beam computed tomography (CBCT) images. Materials and Methods: In this descriptive study, we evaluated CBCT findings of 18 patients i.e. a group of 14 females and 4 males ...

full text

Quality Assurance (QA) for Kilovoltage Cone Beam Computed Tomography (CBCT)

Precise targeting of the tumor is very important and imaging can be immensely helpful in this process. Hence the quality assurance of the imaging systems used to guide the beam is also essential. One could argue that it is as critical as quality assurance for the radiation dose output, since the right amount of radiation dose delivered to the wrong location can be as detrimental as delivering t...

full text

Evaluation of enamel pearls by cone-beam computed tomography (CBCT)

OBJECTIVE The aim of this study was to evaluate the frequency of enamel pearls according to population, sex and tooth groups on Cone-Beam Computed Tomography (CBCT) or Dental Volumetric Tomography (DVT) scans of patients, retrospectively. STUDY DESIGN In this study, 15185 teeth belonging to 768 patients, 430 female and 338 male, was performed cross-sectional examination by CBCT. The volumetri...

full text

Foreign Body in Nasal Cavity: Panoramic and Cone-Beam Computed Tomography (CBCT) Findings

Introduction: Panoramic view as a routine dental radiograph has an important role in diagnosis of other facial abnormalities accompanied with dento- alveolar structures. In this case presentation, we discuss this subject and also the efficacy of cone-beam computed tomography in localization of foreign body in complex anatomy of nasal cavity.

full text

Comparative Study between Electronic Portal Imaging Device (EPID) and Cone Beam Computed Tomography (CBCT) for Radiation Treatment Verifications

Introduction: Electronic Portal Imaging Device (EPID) and Cone Beam Computed Tomography (CBCT) are the preferred tools of Image Guided Radiotherapy (IGRT) and Dose Guided Radiotherapy (DGRT) which have been used for Radiotherapy treatment verifications. As a result, the number of publications dealing with these two tools for radiation treatment verification has increased consi...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 15  issue Special Issue-12th. Iranian Congress of Medical Physics

pages  240- 240

publication date 2018-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023