Application of Guanidine Hcl to Improve Enantioseparation of a Model Basic Drug, Cetirizine, By Capillary Electrophoresis Using Sulfated Β-Cyclodextrin

Authors

  • Afshin Zarghi Pharmaceutical Chemistry Depratment, School of Pharmacy, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
  • Alireza Shafaati Pharmaceutical Chemistry Depratment, School of Pharmacy, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
  • Farrin Sattary Javid Pharmaceutical Chemistry Depratment, School of Pharmacy, Shahid Beheshti University of Medical Sciences, Tehran, Iran
Abstract:

A common approach in resolving enantiomers of chiral basic drugs by capillary electrophoresis (CE) is to use cyclodextrins (especially their anionic derivatives) as chiral selector in the acidic buffer (pH ≤ 3) in normal or reversed (carrier) mode. Then, some organic modifiers are added to the buffer solution if the resolution is not satisfactory. In case of cetirizine (CTN), applying the same approach, i.e. a reversed mode capillary zone electrophoresis (CZE) method with an acidic buffer and sulfated-b-cyclodextrine (S-bCD) as chiral selector, was failed and no complete enantioseparation was achieved. Different organic modifiers, like urea and triethylamine HCl, were used to improve chiral resolution which led to partial resolution of the two peaks. Then, guanidine HCl at a concnetration of 100 mM was added to the running buffer and an acceptable resolution of the enantiomers of the drug was obtained. The method was successfully applied to determine optical purity of a levo-cetirizine (l-CTN) sample.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Chiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis

Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...

full text

Chiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis

Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...

full text

chiral separation of basic and zwitterionic drugs by highly sulfated cyclodextrins using short-end injection capillary electrophoresis highly sulfated cyclodextrins using short-end injection capillary electrophoresis

due to high resolution power of sulfated cyclodextrins (hs-cds), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. experiments were performed on a hp3dce instrument equipped with an on-column diode array uv absorbance detector. fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...

full text

Enantioseparation of chiral sulfoxides and sulfinate esters by capillary electrophoresis.

Forty-one chiral sulfoxides and sulfinate esters were separated using sulfated beta-cyclodextrin and carboxymethyl beta-cyclodextrin as chiral selectors. Binding constants of some analytes to both chiral selectors were measured in order to examine and help explain the observed migration behavior and enantioselectivity trends. Overall, sulfated beta-cyclodextrin separated a greater number of com...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 17  issue 2

pages  505- 512

publication date 2018-04-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023