Application of Bayesian Latent Variable Model for Early Detection of Gestational Diabetes Mellitus Without A Perfect Reference Standard Test by β‐human Chorionic Gonadotropin
Authors
Abstract:
Background and Objectives: Gestational diabetes mellitus (GDM) is a medical problem in pregnancy, and its late diagnosis can cause adverse effects in the mother and fetus. The purpose of this research was to estimate the accuracy parameters of a biomarker for early prediction of gestational diabetes in the absence of a perfect reference standard test. Methods: This study was conducted in 523 pregnant women who presented to Mahdieh Hospital and Taleghani Hospital affiliated with Shahid Beheshti University of Medical Sciences, Tehran, Iran 2017-2018. As a predictor for detecting GDM, beta- human chorionic gonadotropin (β-hCG) measurements were recorded during 14-17th weeks’ gestation in a checklist. The Bayesian latent variable model was used to estimate the sensitivity, specificity, and area under receiver operating characteristic curve (AUC). Bayesian parameter estimation was calculated using the R2OpenBUGS package in R version 3.5.3. Results: The median gestational age was 33 years. In the absence of a perfect reference test, the applied model had a sensitivity, specificity, and AUC of 78% (95% credible interval (CrI): 0.66-0.83), 83% (95% CrI: 0.74-0.89), and 0.72 (95% CrI: 0.64-0.88) for β-hCG, respectively. Conclusion: According to the results of this study, β-hCG may be an acceptable biomarker for early diagnosis of diabetes in pregnant women in the absence of a perfect reference test.
similar resources
Application of adjusted-receiver operating characteristic curve analysis in combination of biomarkers for early detection of gestational diabetes mellitus
Introduction: In medical diagnostic field, evaluation of diagnostic accuracy of biomarkers or tests has always been a matter of concern. In some situations, one biomarker alone may not be sufficiently sensitive and specific for prediction of a disease. However, combining multiple biomarkers may lead to better diagnostic. The aim of this study was to assess the performance of combination of bio...
full textinvestigating the feasibility of a proposed model for geometric design of deployable arch structures
deployable scissor type structures are composed of the so-called scissor-like elements (sles), which are connected to each other at an intermediate point through a pivotal connection and allow them to be folded into a compact bundle for storage or transport. several sles are connected to each other in order to form units with regular polygonal plan views. the sides and radii of the polygons are...
Detection of early pregnancy forms of human chorionic gonadotropin by home pregnancy test devices.
BACKGROUND Home pregnancy testing devices claim >99% diagnostic accuracy for pregnancy and utility on the first day of the missed menses or earlier. We investigated the forms of human chorionic gonadotropin (hCG) in early pregnancy urines, the diagnostic accuracy claim, and the abilities of 15 devices to detect the different forms of hCG. METHODS We measured the concentrations of regular hCG ...
full textApplication of Computational Technique in Design of Classifier for Early Detection of Gestational Diabetes Mellitus
Gestational Diabetes Mellitus (GDM) is defined as any degree of glucose intolerance with onset or first recognition during pregnancy. In view of maternal morbidity and mortality as well as fetal complications, early diagnosis is an utmost necessity in the present scenario. In developing country like India, early detection and prevention will be more cost effective. Oral Glucose Tolerance Test (...
full textan application of equilibrium model for crude oil tanker ships insurance futures in iran
با توجه به تحریم های بین المملی علیه صنعت بیمه ایران امکان استفاده از بازارهای بین المملی بیمه ای برای نفتکش های ایرانی وجود ندارد. از طرفی از آنجایی که یکی از نوآوری های اخیر استفاده از بازارهای مالی به منظور ریسک های فاجعه آمیز می باشد. از اینرو در این پایان نامه سعی شده است با استفاده از این نوآوری ها با طراحی اوراق اختیارات راهی نو جهت بیمه گردن نفت کش های ایرانی ارائه نمود. از آنجایی که بر...
Early screening of gestational diabetes mellitus using maternal hemoglobin A1C: Revision of current screening guidelines
Background: HbA1C has been a known predictor and diagnostic test for diabetes type 2. However, this test has not yet been widely studied in GDM and more importantly no cutoff point has been defined for HbA1C in GDM. We investigated the efficacy of screening during first and second trimester of pregnancy and defined appropriate cutoff points according to HbA1C and FBS for predicting maternal GDM...
full textMy Resources
Journal title
volume 16 issue 1
pages 71- 80
publication date 2020-06
By following a journal you will be notified via email when a new issue of this journal is published.
No Keywords
Hosted on Doprax cloud platform doprax.com