Analytical and comparative investigations on counter flow heat exchanger using computational fluid dynamics

Authors

  • Om Parkash Mechanical Engineering Department, Amity University Haryana-122413, India
  • Rajesh Arora Mechanical Engineering Department, Amity University Haryana-122413, India
Abstract:

This paper presents a comprehensive and exclusive thermodynamic analysis of counter flow heat exchanger under various operating and geometrical conditions. Analysis system (ANSYS) workbench 14.0 has been used for computational analysis and comparison with previous literature has been carried out in view of variable temperature and mass flow rate of hot and cold fluids. An analytical and statistical method of computational fluid dynamics (CFD) analysis is used for simulation and validation of the heat exchanger under steady and dynamic operating conditions. A 3-D model of a heat exchanger having 1000 mm and 1200 mm outside and inside tube lengths with diameter 12.7 mm is designed in ANSYS environment using Renormalization Group (RNG) k-ε approach in order to get the better effectiveness of the system. The variable effects of the steady-state temperature and mass flow rate are investigated. The influence of turbulence over the temperature and pressure profiles is also studied. Moreover, the analytical outcome of the present investigations is compared with that of previous existing literature and found to be in agreement with the previous studies. The proposed analysis presents an in-depth perspective and simulation of temperature gradient profile through the length of heat exchanger. The proposed modified design of heat exchanger along with changing flow direction yields much better results with small computational error 0.66% to 1.004% and 0.83% to 1.05% with respect to change in temperature and mass flow rate respectively.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Effect of Wire Pitch on Capacity of Single Staggered Wire and Tube Heat Exchanger Using Computational Fluid Dynamic Simulation

Single staggered is a design development of normal wire and tube heat exchanger that wires are welded with staggered configuration on two sides. Capacity of wire and tube heat exchanger is the ability of the heat exchanger to release heat. The objective of this study is to analyse the effect of wire pitch (pw) on capacity of single staggered wire and tube heat exchanger. The research...

full text

Multiphase flow and tromp curve simulation of dense medium cyclones using Computational Fluid Dynamics

Dense Medium Cyclone is a high capacity device that is widely used in coal preparation. It is simple in design but the swirling turbulent flow, the presence of medium and coal with different density and size fraction and the presence of the air-core make the flow pattern in DMCs complex. In this article the flow pattern simulation of DMC is performed with computational fluid dynamics and Fluent...

full text

Computational Fluid Dynamics and Heat Transfer Analysis for a Novel Heat Exchanger

.................................................................................................................... 1 Chapter 1.Introduction ............................................................................................... 2 Chapter 2.Computational Domain and Mesh Generation ............................................ 7 2.1 Experimental test section ................................

full text

Heat Exchanger Using Nano Fluid

This paper shows the research work on heat exchanger using nano fluid. In this paper we are using compact heat exchanger as heat transferring device while Al2O3 as a nano fluid. The effect of the nano fluids on compact heat exchanger is analyzed by using ε –NTU rating numerical method on turbo-charged diesel engine of type TBD 232V-12 cross flow compact heat exchanger radiator with unmixed flui...

full text

Computational Fluid Dynamics and Measurement of Flow Field and Wall Temperature Distribution in a Scraped Heat Exchanger Crystallizer

During crystallization the control and effective distribution of heat transfer from the solution to the heat exchanger (HE) plays an important role. Inhomogeneity in temperature on the HE-surface limits the production capacity and increases the tendency of an isolating scale layer formation. To avoid scaling, scraper blades on the HE are commonly used. In a typical axi-symmetric geometry the sc...

full text

Laminar Flow Heat Transfer of a Pseudoplastic Fluid through a Double Pipe Heat Exchanger

An experimental study was carried out to obtain the mean convective heat transfer coefficient of aqueous carboximethyl cellulose (CMC) solutions in double-pipe heat <span style="font-size: 10pt; color:...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 10  issue 1

pages  139- 152

publication date 2020-09-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023