Accuracy Assessment of Freehand Pedicular Screw Placement

Authors

  • Shahab Ilka Bahonar Hospital, School of Medicine, Kerman University of Medcal Science, Kerman, Iran
Abstract:

Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicfractures and were managed with triangular osteosynthesis fixation. However, those with scoliosis deformity wereexcluded from the study. A total of 760 pedicular screws were inserted in C7 to S1 vertebrae without using fluoroscopy.The locations of the screws were assessed by means of computed tomography scan after the surgery. The data wereanalyzed in SPSS software (version 22) using the Chi-square test.Results: Out of 387 thoracic screws and 373 lumbar screws, 65 (16.8%) and 34 (9.1%) screws perforated the pediclewall or vertebral body, respectively. The most frequent locations of perforation in the thoracic and lumbar spine werethe anterior cortex of the vertebral body and medial wall of the pedicle, respectively. Except for the perforation of theanterior vertebral body (P=0.0001), there was no difference between the left and right sides or between thoracic andlumbar sites in terms of the preformation of the screw. No complication was observed due to screw perforation.Conclusion: Our findings revealed the unnecessity of using fluoroscopy in spine surgeries for the insertion of pediculatescrews. In this regard, the use of fluoroscopy for the placement of pedicular screw resulted in similar accuracy andcomplications, as compared to the free hand procedure.Level of evidence: I

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Freehand S2 Alar-Iliac Screw Placement Using K-Wire and Cannulated Screw : Technical Case Series

Objective Among the various sacropelvic fixation methods, S2 alar-iliac (S2AI) screw fixation has several advantages compared to conventional iliac wing screw. However, the placement of S2AI screw still remains a challenge. The purpose of this study was to describe a novel technique of free hand S2AI screw insertion using a K-wire and cannulated screw, and to evaluate the accuracy of the techni...

full text

Acetabular Placement Accuracy With the Direct Anterior Approach Freehand Technique.

BACKGROUND Acetabular cup placement in total hip arthroplasty (THA) has been recognized as an important factor in operative success, and accurate cup placement has been the impetus for novel medical technologies. METHODS This article examines the cup placement in 955 THAs using a freehand Direct Anterior Approach on a standard operating table. Acetabular anteversion and inclination were deter...

full text

Comparison of the accuracy of ventricular catheter placement using freehand placement, ultrasonic guidance, and stereotactic neuronavigation.

OBJECT The objective of this study was to compare the accuracy of 3 methods of ventricular catheter placement during CSF shunt operations: the freehand technique using surface anatomy, ultrasonic guidance, and stereotactic neuronavigation. METHODS This retrospective cohort study included all patients from a single institution who underwent a ventricular CSF shunting procedure in which a new v...

full text

Accuracy Assessment of Using Rapid Prototyping Drill Templates for Atlantoaxial Screw Placement: A Cadaver Study

Purpose. To preliminarily evaluate the feasibility and accuracy of using rapid prototyping drill templates (RPDTs) for C1 lateral mass screw (C1-LMS) and C2 pedicle screw (C2-PS) placement. Methods. 23 formalin-fixed craniocervical cadaver specimens were randomly divided into two groups. In the conventional method group, intraoperative fluoroscopy was used to assist the screw placement. In the ...

full text

Pedicle screw placement accuracy of bone-mounted miniature robot system

This article describes factors affecting the accuracy of transpedicle screw placements performed with the Renaissance robot-guided system and reviews the relevant literature. Between January 2013 and January 2015, Renaissance robot-guided spinal surgery was performed in 125 patients at Kaohsiung Medical University Hospital in Kaohsiung, Taiwan. The surgeries included 662 transpedicle screw impl...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 8  issue 4

pages  519- 523

publication date 2020-07-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023