A stability indicating capillary electrophoresis method for analysis of buserelin

Authors

  • Ernst Kenndler Institute for Analytical Chemistry, Faculty of Chemistry, University of Vienna, A 1090 Vienna. Waehringerstrase 38, Vienna, Austria
Abstract:

A simple and rapid stability indicating method based on capillary zone electrophoresis has been developed and validated for the analysis of buserelin (BUS). The best separations were achieved by using a bare fused silica capillary (75 m i.d.; 65.5 cm total, 57.0 cm effective length), phosphate buffer (pH = 3.00; 26.4 mM), at 35 °C. The sample was hydrodynamically injected at 50 mbar for 5 seconds; the applied voltage was 30 kV and detection was carried out by UV-absorbance at 200 nm. Method validation resulted in the following figures of merit : the method was linear in the concentration range between 0.781 and 500 g/ml (linear regression coefficient 0.9996), accuracy was between 99.3% and 100.9%, intra assay precision was between 0.3% and 1.0% and intermediate precision was between 1.0% and 2.1%. Evaluation of the specificity of the method showed no interference between excipients or products of force degradation and BUS. Under the selected conditions, separation of BUS and its degradation products was completed in less than 10 min, and BUS could be quantified after different stress conditions without any interference. The results enabled the conclusion that under thermal stress upon exposure to 90 °C BUS is degraded by first order kinetics. It was demonstrated that the method can be applied as a rapid and easy to use method for quantification and stability testing of BUS in biopharmaceutical formulations in quality control laboratories.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

a stability indicating capillary electrophoresis method for analysis of buserelin

a simple and rapid stability indicating method based on capillary zone electrophoresis has been developed and validated for the analysis of buserelin (bus). the best separations were achieved by using a bare fused silica capillary (75 m i.d.; 65.5 cm total, 57.0 cm effective length), phosphate buffer (ph = 3.00; 26.4 mm), at 35 °c. the sample was hydrodynamically injected at 50 mbar for 5 seco...

full text

A Stability Indicating Capillary Electrophoresis Method for Analysis of Buserelin

A simple and rapid stability indicating method based on capillary zone electrophoresis has been developed and validated for the analysis of buserelin (BUS). The best separations were achieved by using a bare fused silica capillary (75 μm i.d.; 65.5 cm total, 57.0 cm effective length), phosphate buffer (pH = 3.00; 26.4 mM), at 35 °C. The sample was hydrodynamically injected at 50 mbar for 5 seco...

full text

A Stability Indicating HPLC Method for the Determination of Fluvoxamine in Pharmaceutical Dosage Forms

Fluvoxamine maleate is a selective serotonin reuptake inhibitor, which is used for the treatment of different types of depressive disorders. In the present study, a stability indicating HPLC method was developed and validated for the determination of fluvoxamine maleate. The chromatographic separation was carried out using a Nova-Pak CN column and a mixture of K2HPO4 50 mM (pH 7.0) and acetonit...

full text

A Stability Indicating HPLC Method for the Determination of Fluvoxamine in Pharmaceutical Dosage Forms

Fluvoxamine maleate is a selective serotonin reuptake inhibitor, which is used for the treatment of different types of depressive disorders. In the present study, a stability indicating HPLC method was developed and validated for the determination of fluvoxamine maleate. The chromatographic separation was carried out using a Nova-Pak CN column and a mixture of K2HPO4 50 mM (pH 7.0) and acetonit...

full text

Stability-indicating liquid chromatographic method for valacyclovir

A novel stability-indicating high-performance liquid chromatographic assay method was developed and validated for valacyclovir in the presence of degradation products generated from forced decomposition studies. A Hypersil ODS C-18 (250 x 4.6 mm, packed with 5 micron) column in an isocratic mode with the mobile phase acetonitrile: phosphate buffer (pH3.6) (50:50%v/v) was used. The flow rate was...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 13  issue 3

pages  797- 807

publication date 2014-07-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023