A Nonlinear Voltage Stability Index based on Vector Analysis Method and Measurements of Active and Reactive Powers of Power System

Authors

Abstract:

This paper proposes a new voltage stability assessment method based on vector analysis method. This index extraction process relies on measurements of active and reactive powers from connected buses to the generator buses. Therefore, a limit for beginning of voltage collapse is determined based on the maximum power transfer theory. On the other hand, when the system requires load shedding, a new voltage-frequency load shedding has been employed. This load shedding makes voltage and frequency stabilities be guaranteed via clustering of all loads as allowable and unallowable, and prioritizing allowable cases. Simulation results in DIGSILENT Power Factory software on IEEE-39 bus dynamic test system demonstrate the efficiency of proposed approach with respect to other methods.  

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Active Filter Control Method Based on Direct Power Control for Compensating Reactive Powers due to Unbalanced Voltages and Nonlinear Loads

Active filters have proven to be more effective than passive techniques to improve power quality and to solve harmonic and power factor problems due to nonlinear loads. This paper proposes a control scheme based on the instantaneous active and reactive power. The inverter of this active filter is a three-phase, two-level converter. Space vector technique is used as modulators and pattern genera...

full text

Reactive Power Sensitivity Index based Voltage Stability Analysis to a Real System (400KV System of WBSEB)

The paper presents a method for finding out the weakest bus based on reactive power sensitivity index for a multibus real system. The Voltage Stability Margin (VSM) and change in voltage has also been calculated for the verification for with and without compensation. These techniques are tested on the 400 KV WBSEB system proposed in the 9th plan and results are given to prove the effectiveness ...

full text

‏‎a phonological contrastive analysis of kurdish and english‎‏

deposite the different criticisms on contrastive analysis it has been proved that the results of it(when processed)can be usuful in a tefl environment,specially at the level of phonology.this study is an attempt to compare and contrast the sound systems of kurdish and english for pedagogical aims. the consonants,vowels,stress and intonation of the twolanguages are described by the same model-ta...

15 صفحه اول

active filter control method based on direct power control for compensating reactive powers due to unbalanced voltages and nonlinear loads

active filters have proven to be more effective than passive techniques to improve power quality and to solve harmonic and power factor problems due to nonlinear loads. this paper proposes a control scheme based on the instantaneous active and reactive power. the inverter of this active filter is a three-phase, two-level converter. space vector technique is used as modulators and pattern genera...

full text

a contrastive analysis of concord and head parameter in english and azerbaijani

این پایان نامه به بررسی و مقایسه دو موضوع مطابقه میان فعل و فاعل (از نظر شخص و مشار) و هسته عبارت در دو زبان انگلیسی و آذربایجانی می پردازد. اول رابطه دستوری مطابقه مورد بررسی قرار می گیرد. مطابقه به این معناست که فعل مفرد به همراه فاعل مفرد و فعل جمع به همراه فاعل جمع می آید. در انگلیسی تمام افعال، بجز فعل بودن (to be) از نظر شمار با فاعلشان فقط در سوم شخص مفرد و در زمان حال مطابقت نشان میدهند...

15 صفحه اول

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 12  issue 1

pages  0- 0

publication date 2022-03

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

No Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023