10B Concentration, Phantom Size and Tumor Location Dependent Dose Enhancement and Neutron Spectra in Boron Neutron Capture Therapy

Authors

  • Gh Izadi Vasafi PhD, Department of Physics, Faculty of Sciences, University of Birjand, Birjand, Iran
  • M M Firoozabadi PhD, Department of Physics, Faculty of Sciences, University of Birjand, Birjand, Iran
Abstract:

Background: The amount of average dose enhancement in tumor loaded with 10B may vary due to various factors in boron neutron capture therapy.Objective: This study aims to evaluate dose enhancement in tumor loaded with 10B under influence of various factors and investigate the dependence of this dose enhancement on neutron spectra changes.Material and Methods: In this simulation study, using 252Cf as a neutron source, the average in-tumor dose enhancement factor (DEF) and neutron energy spectra were calculated for various 10B concentrations, phantom with different sizes and for different tumor locations, through MCNPX code. Results: Obtained results showed that the values of average DEF rise with increasing 10B concentration, phantom diameter (˂ 30 cm) and tumor distance from the source, but this increment is not linear.Conclusion: It was concluded that inequality in average dose enhancement rates, in tumor loaded with 10B under influence of various factors in boron neutron capture therapy, is due to non-identical changes of both the thermal neutron flux with increasing same number of 10B atoms and same thickness of scattering material, and the thermal to fast neutron flux ratio with increasing equal distances of tumor from the source.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

A Monte Carlo study of SPECT in boron neutron capture therapy for a heterogeneous human phantom

Background: Boron neutron capture therapy (BNCT) is a binary radiotherapy combining biochemical targeting with neutron irradiation. However, monitoring the boron distribution is a fundamental problem in BNCT. Prompt gamma rays emitted by boron capture reaction can be used to address the issue. Materials and Methods: The general-purpose Monte Carlo toolkits Geant4 and MCNP were used for the simu...

full text

Boron Neutron Capture Therapy

A project aimed at the development of an accelerator facility devoted to Boron Neutron Capture Therapy (BNCT) is ongoing at the National Atomic Energy Commission of Argentina [1]. In a first stage of development, the accelerator will be capable of delivering proton or deuteron beams of 30 mA at about 1.4 MeV which is suitable for neutron production through the 9Be(d,n) reaction. In this context...

full text

Development of a dual phantom technique for measuring the fast neutron component of dose in boron neutron capture therapy.

PURPOSE Research and development of various accelerator-based irradiation systems for boron neutron capture therapy (BNCT) is underway throughout the world. Many of these systems are nearing or have started clinical trials. Before the start of treatment with BNCT, the relative biological effectiveness (RBE) for the fast neutrons (over 10 keV) incident to the irradiation field must be estimated....

full text

شبیه سازی چشمه 7li(p,n)7be جهت استفاده در bnct (boron neutron capture therapy)

با توجه به اینکه امروزه بیماران بسیاری در سراسر جهان از سرطان رنج میبرند،دانشمندان در تلاشند روشهای درمانی جدیدتر و بهتری را کشف کنند .یکی از این روشها "درمان بوسیله گیراندازی نوترون توسط بور (bnct)" نام دارد که میتواند یکی از بهترین روشهای مفید و موثر و جایگزین در درمان سرطانهایی از نوع glioblastoma و melanoma نسبت به روشهای متداولی چون شیمی درمانی یا رادیوتراپی باشد.در این روش هدف انجام واکنش...

Design and Simulation of Photoneutron Source by MCNPX Monte Carlo Code for Boron Neutron Capture Therapy

Introduction Electron linear accelerator (LINAC) can be used for neutron production in Boron Neutron Capture Therapy (BNCT). BNCT is an external radiotherapeutic method for the treatment of some cancers. In this study, Varian 2300 C/D LINAC was simulated as an electron accelerator-based photoneutron source to provide a suitable neutron flux for BNCT. Materials and Methods Photoneutron sources w...

full text

Neutron Tube Design Study for Boron Neutron Capture Therapy Application

Radio-frequency (RF) driven ion sources are being developed in Lawrence Berkeley National Laboratory (LBNL) for sealed-accelerator-tube neutron generator application. By using a 5-cm-diameter RF-driven multicusp source H yields over 95% have been achieved. These experimental findings will enable one to develop compact neutron generators based on the D-D or D-T fusion reactions. In this new neut...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 9  issue 6

pages  653- 660

publication date 2019-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023