مقایسه سنسورهای دیجیتالی Charge-Coupled Device با Photostimulable Phosphor Storage Plate در تشخیص شکستگی عمودی ریشه در دندان‌های اندو شده (مطالعه آزمایشگاهی)

Authors

  • خرازی‌فرد, محمدجواد دانشکده دندانپزشکی
  • سخدری, شیرین گروه رادیولوژی دهان و فک و صورت
  • صفری, سمیه
  • مهرورزفر, پیمان گروه اندودانتیکس
  • پژوتن, مریم گروه رادیولوژی دهان و فک و صورت
Abstract:

  Objective: Vertical root fracture (VRF) is among the most common causes of endodontic treatment failures. This study aims to compare charge-coupled devices (CCD) and photostimulable phosphor plates (PSP) for detection of vertical root fractures in endodontically treated teeth.   Methods: In this diagnostic in vitro study, 40 maxillary anterior teeth were selected and after preparation and root canal filling, their crowns were cut 2mm above the cementoenamel junction (CEJ). The teeth were embedded in a piece of dried bone and radiographed using CCD and PSP with equal geometry at zero and 15° horizontal angles. VRFs were then induced and the fractured fragments were reattached. The teeth were radiographed again. Three observers evaluated the radiographs for detection of fracture line. Data were analyzed using the Proportion test and Wilcoxon’s Signed Ranks test.   Results: No significant difference was found between the two sensors in detection of VRFs [p-value (complete)= 0.592, p-value (absolute)= 1]. The sensitivity of the two sensors for detection of buccolingual and mesiodistal fractures was not significantly different [p-value BL (absolute)= 0.109, p-value BL (complete) 0.180] [p-value MD (complete)=0.593, p-value MD (absolute)= 0.102]. The sensitivity of both sensors for detection of buccolingual fracture was higher than for mesiodistal fractures (p<0.001).   Conclusion: CCD and PSP had equal efficacy for detection of VRFs in endodontically treated teeth.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

اثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین

Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...

full text

اثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین

Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...

full text

diagnostic accuracy of charge-coupled device sensor and photostimulable phosphor plate receptor in the detection of external root resorption in vitro

background and aims. early diagnosis of external root resorption is important for accurate treatment. the purpose of this study was to compare the efficacy of a charge-coupled device (ccd) sensor and a photostimulable phosphor (psp) plate receptor in the diagnosis of artificial external root resorption. materials and methods. in this diagnostic in-vitro study, 40 maxillary incisors were mounted...

full text

Diagnostic Accuracy of Charge-coupled Device Sensor and Photostimulable Phosphor Plate Receptor in the Detection of External Root Resorption In Vitro

Background and aims. Early diagnosis of external root resorption is important for accurate treatment. The purpose of this study was to compare the efficacy of a charge-coupled device (CCD) sensor and a photostimulable phosphor (PSP) plate receptor in the diagnosis of artificial external root resorption. Materials and methods. In this diagnostic in-vitro study, 40 maxillary incisors were mounted...

full text

توموگرافی خطی با فیلم و Photostimulable Phosphor Plate در طرح درمان ایمپلنت در مندیبل

Background and Aims: Radiographic examination prior to implant placement is often complemented with tomography for location of vital anatomic structures and evaluation of bone volume. The aim of this study was to evaluate the accuracy of Photostimulable Phosphor Plate system with that of conventional film-screen in mandibular pre-implant linear tomography Materials and Methods: In this test eva...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 32  issue None

pages  23- 29

publication date 2014-02

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

No Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023