مطالعه توزیع دز چشمه براکی تراپی 103Pd در درمان سرطان‌های مجاور با بافت‌های چربی و ماهیچه به روش مونت کارلو با استفاده از کد MCNP4C

Authors

  • احمدی, ام لیلا دانشکده فیزیک
Abstract:

Introduction: The dosimetry of the brachytherapy sources is performed in the water source medium according to protocol TG-43U1. To achieve a resonable results on treatment, the use of the water material for all body tissues can be one of the faulty sources in delivering the correct dose to the tumor. Thus, we have focused on the dosimetry parameters in fat density 0.95 gr/cm3 and the muscle with density 1.05 gr/cm3 in the present study. The results are compared with the results of the water phantom to show the accurate accessment via the differences of the results. Methods: Dissymmetry simulations for determining the parameters of the radial dose function and the anisotropy function in fat tissues, muscle and water phantom distances and different angles has been using MCNP4C code. Results: The greatest relative differences of the phantom radial dose function of the fat tissue at distances below 1cm approximately reached 13%; and this rate increased, when the distance from the source increased; whereas at the distance of 5cm from the source, it approximately reached 167%. In the muscle tissue, the relative difference of these parameters was about 3% at the distance of 0.5cm, while at the distance of 5cm from the source, it approximately increased 16%. The maximum relative difference of the anisotropy parameter of the fat and muscle tissue phantom compared with the water were observed more than 2% and 3%, respectively. Conclusion: In the clinical application of the 103Pd brachytherapy source, which is contracted in the treatment of the adjacent malignant tumors to the fat and muscle tissues, the correct decisions must be applied on the tissue dosimetry parameters in the treatment planings according to the tables  of 3, 4, 5 and 6 in this study.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

مطالعه توزیع دز چشمه براکی تراپی ۱۰۳pd در درمان سرطان های مجاور با بافت های چربی و ماهیچه به روش مونت کارلو با استفاده از کد mcnp۴c

مقدمه: دزیمتری چشمه های براکی تراپی طبق پروتکل tg-43u1 در محیط آب اطراف چشمه انجام می شود. برای رسیدن به یک نتیجه مناسب درمان، استفاده از ماده آب برای همه بافت های بدن می تواند یکی از منابع خطا در رسانیدن دز صحیح به تومور مورد نظر داشته باشد؛ از این رو در این مطالعه به تعیین پارامترهای دزیمتری بافت های متفاوت چربی با چگالی gr/cm3 95/0 و ماهیچه با چگالی gr/cm3 05/1 پرداخته ایم تا با مقایسه آن ها...

full text

ارزیابی دز رسیده به پروستات و چند اندام حساس در براکی تراپی پروستات با استفاده از کد مونت کارلو در سه رادیوایزوتوپ131Cs ، 103Pd و 125I

  Using the Monte Carlo N-Particle computer code (MCNP), doses were calculated for organs of interest such as the stomach, prostate, liver, and kidneys while patients were undergoing prostate brachytherapy. This research is important because the doses delivered to the prostate are extremely high and the organs near the prostate are potentially at risk of receiving high doses of radiation, ...

full text

تخمین دز پروستات و اندام های مجاور آن در حین براکی تراپی پروستات و بررسی پراکندگی بر میزان دز با استفاده از کد MCNP4C

In regard with increasing use of brachytherapy for treatment of cancer, especially prostate cancer, dosimetry of the organs surrounding prostate is necessary. The received dose by prostate is relatively high and the healthy organs surrounding prostate are potentially at a risk of high dose too. In this paper, the doses delivered to the prostate and organs of interest were calculated by MCNP4C c...

full text

بررسی اثر ناهمگنی بافت استخوان بر توزیع دز چشمه ی براکی تراپی ۱۰۳pd مدل med۳۶۳۳ به روش مونت کارلو

در تعیین پارامترهای دزیمتری چشمه­های براکی­تراپی تنها با به کار بردن محیط آب اطراف چشمه با چگالی تقریباًgr/cm3 1، برای همه­ی بافت­های بدن نمی­توان به نتیجه­ی درستی دست یافت.در این مطالعه با انتخاب بافت استخوان با چگالیgr/cm340/1 و با استفاده از کد مونت کارلویmcnp4c شبیه­سازی­های لازم برای تعیین پارامترهای دزیمتری در فواصل و زاویه­های مختلف انجام شده و اختلاف نسبی بین این دو حالت با یکدیگر مقایسه...

full text

مقایسه تأثیر وضعیت طاق باز و دمر بر وضعیت تنفسی نوزادان نارس مبتلا به سندرم دیسترس تنفسی حاد تحت درمان با پروتکل Insure

کچ ی هد پ ی ش مز ی هن ه و فد : ساسا د مردنس رد نامرد ي سفنت سرتس ي ظنت نادازون داح ي سکا لدابت م ي و نژ د ي سکا ي د هدوب نبرک تسا طسوت هک کبس اـه ي ناـمرد ي فلتخم ي هلمجزا لکتورپ INSURE ماجنا م ي دوش ا اذل . ي هعلاطم ن فدهاب اقم ي هس عضو ي ت اه ي ندب ي عضو رب رمد و زاب قاط ي سفنت ت ي هـب لاتـبم سراـن نادازون ردنس د م ي سفنت سرتس ي لکتورپ اب نامرد تحت داح INSURE ماجنا درگ ...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 24  issue 8

pages  618- 629

publication date 2016-11

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

No Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023