توموگرافی خطی با فیلم و Photostimulable Phosphor Plate در طرح درمان ایمپلنت در مندیبل
Authors
Abstract:
Background and Aims: Radiographic examination prior to implant placement is often complemented with tomography for location of vital anatomic structures and evaluation of bone volume. The aim of this study was to evaluate the accuracy of Photostimulable Phosphor Plate system with that of conventional film-screen in mandibular pre-implant linear tomography Materials and Methods: In this test evaluation study, tomograms of 2 dry human mandibles were taken using the both film-screen and Photostimulable Phosphor Plate. 10 sites were selected in each mandible and marked with gutta-percha. Distance of superior border to the mandibular canal and the total height and width of mandible were measured on the tomograms and also on the mandibles after sectioning. The radiographic values were compared with real ones. Results: After correction of tomographic values by the magnification factor of the unit, the mean of absolute differences with reality in linear tomography using film-screen and Photostimulable Phosphor Plate for height of mandible were 0.59mm (SD=0.54) and 0.65mm (SD=0.72), respectively. The mean of absolute differences with reality in linear tomography using film-screen and Photostimulable Phosphor Plate for width of mandible were 0.34mm (SD=0.33) and 0.31mm (SD=0.33), respectively. In localization of the mandibular canal, the mean of absolute differences with reality were 0.54mm (SD=0.30 ) and 0.52mm (SD=0.56) for linear tomography using film-screen and Photostimulable Phosphor Plate, respectively. In linear tomography using film-screen, 100% of measurements for localization of the canal, 80% of height and 95% of width were with in ± 1mm error limits. In linear tomography using Photostimulable Phosphor Plate, 75% of measurements for localization of the canal, 75% of height and 95% of width were within ± 1mm error limits. There was no significant difference between linear tomography using film-screen and Photostimulable Phosphor Plate in localizing the mandibular canal and height and width estimation (P>0.05). Conclusion: The accuracy of linear tomography using film-screen and Photostimulable Phosphor Plate in height and width estimation and localization of the canal is within acceptable limits.
similar resources
توموگرافی خطی با فیلم و photostimulable phosphor plate در طرح درمان ایمپلنت در مندیبل
زمینه و هدف: بررسی رادیوگرافیک قبل از جایگذاری ایمپلنت اغلب با توموگرافی برای مشخص کردن موقعیت ساختار آناتومیک حیاتی و ارزیابی استخوان کامل می شود. هدف از این مطالعه بررسی دقت توموگرافی خطی با استفاده از فیلم و photostimulable phosphor plate جهت ارزیابی کمیت استخوان مندیبل برای استفاده در طرح درمان ایمپلنت بود.
full textاثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین
Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...
full textاثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین
Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...
full textمقایسه دقت توموگرافی خطی و سی تی اسکن جهت بررسی کمیت استخوان در درمان ایمپلنت
زمینه: بررسی کمیت استخوان فک جهت جایگزینی دندانهای از دست رفته از مسایل مهم قبل از درمان است. هدف: مطالعه به منظور مقایسه دقت توموگرافی خطی و سیتیاسکن در اندازهگیریهای خطی بر روی نواحی مشخصی از فک پایین خشک انجام شد. مواد و روشها: این مطالعه تحلیلی در سال 1390 بر روی 2 مندیبل خشک انجام شد که به طور کامل بیدندان بودند. 27 نقطه با استفاده از گوتاپرکای شماره 60 ، معین و تصاویر توموگر...
full textبررسی دقت توموگرافی معمولی اسپیرال در تخمین ارتفاع استخوان آلوئول مندیبل در درمان ایمپلنت های دندانی
مقدمه: ارزیابی دقیق استخوان باقی مانده آلوئول به وسیله توموگرافی معمولی (conventional tomography) در درمان ایمپلنت اهمیت دارد. هدف از این مطالعه بررسی دقت توموگرافی های معمولی اسپیرال در تخمین ارتفاع استخوان آلوئول در ناحیه خلف مندیبل بود. مواد و روش ها: در مطالعه تجربی حاضر تعداد 30 ناحیه بی دندانی در فک پایین بیماران انتخاب شد و توسط توموگرافی معمولی مورد ارزیابی قرار گرفت. ارتفاع استخوان باق...
full textImproved computed radiography image quality from a BaFl:Eu photostimulable phosphor plate.
Recent advances in the design of photostimulable phosphor (PSP) plates for computed radiography (CR) systems have made it possible to manufacture plates made of BaFI:Eu phosphor material in the cassette form. The image quality of this plate, six BaF(Br,I):Eu plates, and one BaFBr:Eu plate were evaluated in terms of presampling modulation transfer function (MTF), normalized Wiener spectra (WSN),...
full textMy Resources
Journal title
volume 23 issue None
pages 128- 133
publication date 2010-10
By following a journal you will be notified via email when a new issue of this journal is published.
No Keywords
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023