تعیین موقعیت لوله‌های تراشه دابل لومن در جراحی توراکس: کمپلیانس بگ در مقایسه با برونکوسکوپ فیبراوپتیک

Authors

  • بنازاده, محمد گروه جراحی توراکس دانشگاه علوم پزشکی تهران
  • حسینی, محمد رضا گروه بیهوشی دانشگاه علوم پزشکی تهران
Abstract:

Background: Lung separation is the basis of thoracic anesthesia, which is performed by different instruments. Checking probable malpositioning of tracheal tube needs fiberoptic bronchoscopy. The aim of this study was to compare respirator suggested compliance with fiberoptic findings in detecting major tracheal tube malpositioning.Methods: A total of 256 patients undergoing thoracic surgery with double-lumen tracheal tube insertion in Imam Khomeini Hospital, Tehran, Iran, during 2010-11 were divided into three groups (n=86). We used left-sided double-lumen tube (DLT) for left or right-sided surgeries (groups 1 and 2), and right-sided DLT for left-sided surgeries (group 3). The position of the tubes was evaluated and compared using bag compliance versus fiberoptic bronchoscopy.Results: The mean age of the study population was 44.7±13.4 (16-73) years, while 155 (59.9%) were male. The sensitivity, specificity, positive and negative predictive values, and the accuracy of bag compliance test for left-sided DLT in supine position were 40% (95% CI: 20-60%), 99% (95% CI: 96-99%), 84% (95% CI: 54-94%) 92% (95% CI: 88-95%) and 92% (95% CI: 87-95%), respectively. The above-mentioned variables for lateral decubitus position respectively were 27%, 98%, 76%, 89%, and 88%. Malpositioning was more prevalent in right-sided DLTs (P=0.02).Conclusion: Based on the results of this study, and the high specificity, positive predictive value, and accuracy of bag compliance test, its use is encouraged as an alternative to fiberoptic bronchoscopy for checking DLT position, specially, in emergent surgeries or when fiberoptic bronchoscopy is unreachable due to lack of expertise or personnel.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

تعیین موقعیت لوله های تراشه دابل لومن در جراحی توراکس: کمپلیانس بگ در مقایسه با برونکوسکوپ فیبراوپتیک

زمینه و هدف: اساس بیهوشی در جراحی توراکس جداسازی ریه ها می باشد. هدف از این مطالعه استفاده از معیار کمپلیانس بگ به منظور جاگذاری صحیح لوله تراشه دابل لومن می باشد.روش بررسی: بیماران کاندید جراحی توراکس در سه گروه تحت لوله گذاری با دابل لومن چپ برای توراکوتومی راست و یا چپ (گروه یک و دو) و یا لوله گذاری با دابل لومن راست برای توراکوتومی چپ (گروه سه) قرار گرفتند (سه گروه 86 نفره). در وضعیت سوپاین...

full text

اثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین

Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...

full text

اثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین

Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...

full text

ارزیابی مقایسه ای توموگرافی اسپیرال در تعیین موقعیت دندان‏های نهفته فک بالا با نتایج بعد از جراحی

مقدمه: برای تشخیص نهفتگی دندان‏های کانین معمولا از رادیوگرافی‏های کانونشنال استفاده می‏شود. اما این رادیوگرافی‏ها اطلاعات کاملی را در بعد سوم فراهم نمی کنند. در این مواقع از توموگرافی و توموگرافی کامپیوتری برای کسب اطلاعات جزئی در مورد موقعیت دندان نهفته استفاده می‏شود. هدف از انجام این مطالعه بررسی دقت توموگرافی اسپیرال در تعیین موقعیت دندان‏های نهفته فک بالا بود. مواد و روش‏ها :در این مطالعه...

full text

مقایسه تأثیر وضعیت طاق باز و دمر بر وضعیت تنفسی نوزادان نارس مبتلا به سندرم دیسترس تنفسی حاد تحت درمان با پروتکل Insure

کچ ی هد پ ی ش مز ی هن ه و فد : ساسا د مردنس رد نامرد ي سفنت سرتس ي ظنت نادازون داح ي سکا لدابت م ي و نژ د ي سکا ي د هدوب نبرک تسا طسوت هک کبس اـه ي ناـمرد ي فلتخم ي هلمجزا لکتورپ INSURE ماجنا م ي دوش ا اذل . ي هعلاطم ن فدهاب اقم ي هس عضو ي ت اه ي ندب ي عضو رب رمد و زاب قاط ي سفنت ت ي هـب لاتـبم سراـن نادازون ردنس د م ي سفنت سرتس ي لکتورپ اب نامرد تحت داح INSURE ماجنا درگ ...

full text

تعیین موقعیت عوارض با GPS

جهت دستیابی به داده­ های بسیار دقیق جغرافیایی با استفاده از GPS نیازی به اقدامات مهم و تهورآمیزی نمی­ باشد. ورود به این تکنولوژی جدید نیاز به مشاهد دقیق در بررسی­ های انجام شده در مورد هزینه و تصحیح خطاهای آن دارد. انگیزه اصلی که در پشت توسعه سیستم تعیین موقعیت جهانی GPS وجود دارد، همان نیاز به ابزار بسیار دقیق جهت ناوبری است که در واقع معلوم نمودن موقعیت – سرعت و زمان با دقت­ های بسیار بالا می...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 70  issue None

pages  480- 487

publication date 2012-11

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

No Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023