بهینه سازی نگاره های MRA مغز با استفاده از ماده کنتر است زا در میدان مغناطیسی 1.5 تسلا

Authors

  • بلوری , بهرام
  • رحیمی , سیدعلی
  • رفیعی , بهروز
  • ریاحی عالم , نادر
  • عقابیان , محمدعلی
  • قناعتی , حسین
  • هاشمی , حسن
Abstract:

Background and purpose: Selection of suitable parameters for brain MRA requires accurate measures, because the image quality depends on the location of arteries, veins and also the velocity differences of blood, taking into account the low blood flow in small veins and arteries, use of paramagnetic contrast media is recommended. Hence, in present study, we investigated the imaging optimization of brain vessels using contrast media in 1.5 T field. Materials and Methods: For image optimization blood T1 was estimated after the injection of 0.1mmol/kg of Gd-DTPA and the relative blood signals were measured at T1=300, 600, 900 and 1200ms using TR=20ms and TE=7ms parameters. Ernest angle and relative signal increased as the T1 decreased. MRA was obtained in three groups, each including five volunteer patients using parameters TR=20ms, TE=7ms and flip angle 10, 20 & 30 degrees in two series without and during contrast injection. Signals of carotid, M.C.A and thorcolar herofili and SD in air were measured and it was shown that in 20 degrees flip angle, C/N was maximum. At the last stage, three series of MRA, without, during c.i and 15 minutes after c.i where obtained in 20 volunteer patients using parameters TR=20ms, TE=7ms and flip angle 20 degrees and calculated C/N . Results: After statistical analysis the highest C/N was observed during c.i MRA. Paired t-student test was performed to compare the differences between the C/N ratios. For clinical purposes one vein and two arterles were graded in 5 definite levels. Conclusion: Results indicated an important effect of paramagnetic contrast media on better observing of small arteries and vein. The best quality was taken during c.i, but in some arteries contrast media did not improve the quality of MRA

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

بهینه سازی نگاره های mra مغز با استفاده از ماده کنتر است زا در میدان مغناطیسی ۱.۵ تسلا

سابقه و هدف: برای انجام آنژیوگرافی با استفاده از رزونانس مغناطیسی (magnetic resonance angiography) mra از مغز با توجه به وضعیت خاص شریا ن ها و وریدهای آن که دارای سرعت های متفاوت خون است، نه تنها باید در انتخاب پارامترهای تصویربرداری دقت خاصی داشت، بلکه باید موقعیت تشریحی عروق مورد مطالعه را نیز در نظر گرفت؛ به نحوی که به علت سرعت آهسته جریان خون در سیستم وریدی و شریان های کوچک در مغز استفاده ا...

full text

اثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین

Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...

full text

اثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین

Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...

full text

نگاره برداری با استفاده از رزونانس مغناطیسی هسته ای

Basic physical principles of nuclear magnetic resonance imaging (N.M.R.I), a nonionizing medical imaging technique, are described. Principles of NMRI with other conventional imaging methods, ie, isotope scanning, ultrasonography and radiography have been compared. T1 and T2 and spin density (S.D.) factors and different image construction techniques based on their different combinations is discu...

full text

استفاده از پرتو الکترونی تحت تاثیر میدان مغناطیسی برای بهینه سازی الگوی دوز تجویزی در بیماران تحت رادیوتراپی

زمینه و هدف: در رادیوتراپی برای درمان توده های سرطانی بسته به عمق و نوع تومور اغلب از پرتوهای فوتونی یا الکترونی استفاده می­شود که به ناچار بافتهای سالم در مسیر اشعه مقداری دوز دریافت می­کند. از آنجا که میدان مغناطیسی موجب انحراف در مسیر پرتو الکترونی می­شود می­توان از این خاصیت استفاده نمود و واگذاری دوز از بافت­های سالم را به طرف بافتهای تومورال هدایت کرد. روش بررسی:...

full text

بررسی اثر میدان مغناطیسی با شدت های 2 و 8 میلی تسلا بر تثبیت حافظه فضایی موش بزرگ آزمایشگاهی

سابقه و هدف: میدان های مغناطیسی موجود در محیط زندگی انسان می توانند بر یادگیری و حافظه اثر نمایند از این رو این مطالعه به منظور بررسی اثر میدان مغناطیسی کوتاه مدت با شدت های 2 و 8 میلی تسلا بر تثبیت حافظه در موش بزرگ آزمایشگاهی انجام گرفت. مواد و روشها: در این پژوهش از 36 سر موش نر سه تا 4 ماهه نژاد ویستار با وزن حدود 15±235 گرم استفاده شد که به صورت تصادفی به سه گروه کنترل، تابش گیری 2 و 8 میل...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 16  issue 54

pages  27- 34

publication date 2006-10

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

No Keywords

Hosted on Doprax cloud platform doprax.com