بررسی کارایی اسکرابر ونچوری در جمع‌آوری گردوغبار هوابرد Fe2O3 در یک واحد آهن‌سازی

Authors

Abstract:

Background and aims: Steel industry plays an important role in air pollution and particulate emissions released to the environment. The Venturi scrubber is one of the most important scrubbers and components at local exhaust ventilation which has a lot of application to control of the contaminants emissions to the atmosphere in the steel industry. On the other hand, the efficiency of this equipment depends to use and how to use, therefore aim of this study is determination of the efficiency of a venturi scrubber at an iron making unit. Methods: This research is a descriptive cross-sectional study to determination of the venturi scrubbers efficiency in collection of particle different sizes. Sampling to be fulfilled based on BS 3405 method and duct internal isokinetic sampling at 30 l/min flow before and after venturi scrubber using of the sampling sequence include a set of probe with standard inlet nozzle, sampler and particles classifier (the four-stage cascade impactor) which followed with the flow control and measurement equipment. Finally, the samples were analyzed using gravimetric method and the results were analyzed using spss 16 Software. Results: The fluid velocity was in the throat of the scrubber 71.4 m/s and the ratio of liquid to gas 1.12 l/m3. The mean of total dust concentration was before and after Venturi, respectively 6900mg/m3 and 983mg/m3. The overall efficiency of the venturi scrubber was 85.3%. The maximum removal of the particle size distribution was respectively to particle size 15&mu;m<, 15-4&mu;m, 4-1&mu;m and <1&mu;m&nbsp; and 93.2%, 90.6%, 79.4%, 30.4%. Conclusion: It is concluded that scrubber&rsquo;s efficiency increased in parallel increasing in particle aerodynamic diameter, but its removal efficiency was not achieved to desirable level for particle size lower than 1 &mu;m because of inappropriate modification in some design parameters such as nozzles. Regarding decrease in load pollutant input, performance of this scrubber is not acceptable even for large particle sizes.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

بررسی کارایی اسکرابر ونچوری در جمع آوری گردوغبار هوابرد fe۲o۳ در یک واحد آهن سازی

زمینه و هدف: کارخانه های فولاد از جمله صنایعی هستند که نقش مهمی را در آلودگی هوا و  انتشار آلاینده های ذره ای به محیط دارند. اسکرابر ونچوری یکی از مهم ترین  اجزا و پالایشگرهایی است که در سیستم های تهویه برای کنترل انتشار آلاینده ها به اتمسفر در صنعت فولاد کاربرد زیادی دارد. از طرفی کارایی این وسیله به نحوه کاربری و استفاده از آن بستگی دارد، لذا این مطالعه با هدف تعیین کارایی اسکرابر ونچوری در ی...

full text

اثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین

Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...

full text

اثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین

Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...

full text

بررسی کارایی هودهای سیستم تهویه مکنده موضعی در کنترل گردوغبار Fe2O3 در فرایند سرند اکساید واحد آهن سازی یکی از صنایع فولاد

&nbsp; Background & Objectives : Local exhaust ventilation system (LEV) is one of the most common engineering controls methods for the chemical agents in workplaces. This study aimed to determine the efficiency assessment of the LEV system for control of Fe2O3 dust in the process of oxide screen unit at iron making in steel industry . &nbsp; Methods : The LEV system with an extensive network...

full text

کاهش انتشار آلاینده های هوا در واحد کت کراکر جدید پالایشگاه آبادان توسط اسکرابر

در فرایند واحد کت کراکر ضمن عملیات کک سوزی و احیاء کاتالیست در برج احیاء به میزان 230 تن در ساعت گازهای سوخته شده تولید می گردد. میزان آلاینده SO2 در جریان گاز ورودی به اسکرابر 2/0 درصد مولی و حداکثر ذرات کاتالیست همراه آن 100 میلی گرم در متر مکعب می باشد. در این تحقیق فرایند جذب با بافر کاستیک فسفات که از نظر اقتصادی، راندمان جذب در اولویت بود انتخاب و توسط نرم افزار HYSYS Refinery شبیه سازی گ...

full text

ارزیابی عملکرد سیستم تهویه مکنده موضعی در کنترل گردوغبار اکسید آهن (II) در یک واحد آهن سازی

Introduction: Adherence to the design values and ventilation standards (VS) after installing and also maintaining continuous work of ventilation system with maximum performance throughout its life are amongst the reasons of ventilation systems monitoring. Therefore, the aim of this study was to evaluate performance of local exhaust ventilation system for control of dust by measuring the operati...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 13  issue 3

pages  33- 46

publication date 2016-09

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

No Keywords

Hosted on Doprax cloud platform doprax.com