بررسی میزان انطباق بخش های رادیوگرافی در بیمارستان های دولتی استان مازندران با راهنمای استاندارد CEC و عوامل مرتبط با آن در سال 1390

Authors

  • فلاح محمدی , غلامرضا
  • یوسفی, سهراب
Abstract:

Abstract Background and purpose: The Commission of European Communities (CEC) has developed a guideline in which many common radiographic techniques are determined. Following these guidelines will reduce patient dose and good quality image is obtained. Noncompliance of radiographic centers with standard guidelines not only leads to reduction in radiographic image quality but also wastes resources and increases the rate of radiographic repeat and the risk of radiation damage. In this research X-ray departments’ adherence to European guidelines was assessed. Materials and methods: In this descriptive study nine hospitals of Mazandaran province with high reception were studied. Adoption of technical data on adult patients in radiographs of lung (PA), abdomen (AP), pelvis (AP), and lumbar spine (AP and lateral) was assessed. The technical information including name of hospital, number of radiographic room, type of test (chest, abdomen, etc.), exposure condition (kVp), the x-ray tube to the patient distance (FFD), the use or non-use of automatic exposure control (AEC) were recorded. The equipment information including type of film- screen and grid ratio were also recorded. The data was then compared with the standards introduced by CEC. Results: None of the hospitals followed the AEC system. The grid ratio used in radiographic table in all hospitals did not correspond to the recommended value. This study shows that all hospitals follow the FFD recommended by the CEC in the radiographs of the abdomen, pelvis, and lumbar (AP and Lat.). In radiographs of the lungs only one hospital did not follow the FFD selection of the CEC. Conclusion: In this study the highest rate of compliance with the CEC standard was observed in film-screen selection and the least rate of adherence was found in AEC system, grid ratio and selection of kVp in chest radiographs. The studied X-ray departments’ adherence to European guidelines was 43%.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

بررسی میزان انطباق بخش های رادیوگرافی در بیمارستان های دولتی استان مازندران با راهنمای استاندارد cec و عوامل مرتبط با آن در سال ۱۳۹۰

سابقه و هدف: کمیسیون جامعه اروپایی (the commission of european communities-cec) راهنمایی را تدوین کرده است که در آن برای بسیاری از آزمون های رادیوگرافی رایج، بهترین شرایط کارتعیین گردیده که با ملاحظه منفعت بیمار با پیروی از آن هردو مولفه کیفیت تصاویر رادیوگرافی و کاهش میزان دز به بیمار تضمین می گردد. عدم انطباق مراکز رادیولوژی با راهنماهای استاندارد نه تنها منجر به کاهش کیفیت تصاویر رادیوگرافی ...

full text

اثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین

Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...

full text

اثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین

Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...

full text

بررسی خطاهای ناخواسته رایج در بیهوشی و عوامل مرتبط با آن در بیمارستان های دولتی استان مازندران

Background and purpose: Many drugs are used in anesthesia that have rapid direct effect on nervous system and cardiovascular system. An error in prescribing them has a lot of risks. The aim of this study was to determine the characteristics of errors associated with anesthesia and operating room in state hospitals in Mazandaran province. Materials and methods: In this cross-sectional study a q...

full text

بررسی میزان تکرار تصاویر رادیوگرافی و عوامل مرتبط با آن در مراکز درمانی بخش های دولتی شهرستان ساری در سال 1387

Background and purpose: Radiographic film repeat rate assessment is performed to appropriate profiting of existence resources in therapeutic wards. Multiple exposures of x-ray generators due to repeated radiographic examination can lead to amortization of the radiographic facilities and decrease their longevity and also increases the cost of facilities repair. On the other hand, its therapeut...

full text

بررسی میزان تکرار تصاویر رادیوگرافی دیجیتال و عوامل مرتبط با آن در مراکز درمانی بخش های دولتی شهرستان ساری در سال 1396

  Background and purpose: The radiographic imaging repeat rate (RR) in digital and conventional imaging systems is considered as a quality control indicator. RR increases the unnecessary patient and staff dose, prevents the loss of resources and depreciation of systems and increases the time for radiographic services. In this study, digital radiographic RR and its related factors were inv...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 23  issue 99

pages  45- 52

publication date 2013-04

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

No Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023