بررسی ترکیبات آلی فرار در هوای خروجی دستگاههای بی خطرساز پسماندهای بیمارستانی با حرارت پایین در چهار بیمارستان شهر تهران در سال1390
Authors
Abstract:
Background and aims: Application of low heat devices was increased for infectious waste sterilizing in many hospitals in Iran. Studies have shown that the generation of volatile organic compounds (VOCs) and hazardous materials is most probable in the exhaust air of these devices. The main objective of this research is study of VOCs ( in the exhaust air from low heat sterilizer devices of four hospitals in Tehran city. Methods: This research was accomplished in some hospitals using sterilizer devices such as: Hydroclave, Autoclave-shredder, Autoclave without shredder and Heat dryer. Ten samples were taken from each device every week from April to July 2011. Sampling was done by NIOSH 1501 method. Samples were analyzed in two qualitative and quantitative phases by GC-MASS and the obtained results were compared with occupational exposure short term limits (OEL- STEL) recommended by Center for Environmental and Occupational Health, Iranian Ministry of Health. Results: In the first phase of research (qualitative analysis), in 90% of samples only BTEX compounds(Benzene, Toluene, Ethyl Benzene and Xylene) were observed. Based on the results of the second phase, the highest and the lowest concentration of BTEX with 9.35 ppm and 1.25 ppm were determined to be related to Autoclave-shredder and Autoclave without shredder, respectively. According to exhaust air clarity, Autoclave without shredder, Hydroclave, Heat dryer and Autoclave-shredder were scored from 1 to 4, respectively. Conclusion: The concentrations of Benzene, Toluene, Ethyl Benzene and Xylene in all samples were lower than the occupational exposure short term limits. The presence of VOCs in the majority of collected samples, considering the short lifetime of these devices (between 3 to 9 months), confirmed that there is a high potential risk of exposureresulted by these devices. Therefore, monitoring of exhaust air quality of such devices is required. Keywords : low heat waste sterilizers hospital wastes volatile organic compounds BTEX air
similar resources
بررسی ترکیبات آلی فرار در هوای خروجی دستگاههای بی خطرساز پسماندهای بیمارستانی با حرارت پایین در چهار بیمارستان شهر تهران در سال۱۳۹۰
زمینه و هدف : کاربرد دستگاههای بی خطرسازی پسماند با حرارت پایین در بیمارستان های کشور رو به افزایش است. احتمال تولید ترکیبات آلی فرار( vocs ) و خطرناک در هوای خروجی از این دستگاهها وجود دارد. هدف اصلی این تحقیق بررسی ترکیبات آلی فرار در هوای خروجی این دستگاهها در چهار بیمارستان شهر تهران می باشد. روش بررسی : این تحقیق در بیمارستان های مجهز به دستگاههای بی خطرسازی از نوع: هیدروکلاو، اتوکلاو دار...
full textاثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین
Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...
full textاثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین
Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...
full textسنجش میزان کل ترکیبات آلی فرار در هوای آزاد و محیط داخلی چهار مهدکودک در شهر اهواز
زمینه: امروزه ترکیبات آلی فرار به عنوان یکی از شناختهترین آلایندههای هوا به ویژه در محیطهای داخلی محسوب میگردند. هدف اصلی این مطالعه سنجش میزان TVOC در هوای محیط داخل و آزاد اطراف مهدکودکهای مورد نظر و بررسی ارتباط غلظتهای داخل و خارج با یکدیگر بود. مواد و روشها: سنجش در 4 مهدکودکِ شهر اهواز و در پنج روز متوالی بین ساعات 9 تا 10 صبح صورت گرفت.به طور کلی 40 نمونه جمعآوری شد. در این مطالعه...
full textارزیابی ترکیبات آلی فرار در هوای شهر خرم آباد و مقایسه آن با استانداردهای موجود
Background : The first step in controlling pollutants is to measure and analyze them, because comparing them with standards and practically controlling them will not become possible without full awareness of the qualities and quantities of pollutants. The present study was conducted to assess and determine the amount of volatile organic compounds in the air in Khorramabad, Iran. Methods and Mat...
full textتحلیل مکانی ترکیبات آلی فرار در هوای شهر تهران با استفاده از نرم افزار آرک ویو
کلانشهر تهران از نظر آلودگی هوا در رده ی بالایی قرار گرفته است و این امتیاز منفی، سلامتی ساکنان این منطقه را تهدید می کند. ترکیبات آلی فرار و به خصوص بتکس ها، گروه بزرگی از آلاینده های هوا هستند که نقش بحرانی در شیمی اتمسفر شهر تهران بازی می کنند. بنزن، مهم ترین ترکیب این آلاینده ها بوده و موجب بروز سرطان خون و بیماری های مرتبط با آن می شود. ترکیبات آلی فرار بایستی در مکان های مختلف شهری شناسای...
full textMy Resources
Journal title
volume 11 issue 1
pages 44- 54
publication date 2014-04
By following a journal you will be notified via email when a new issue of this journal is published.
No Keywords
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023