اصلاح حرکت در تصویربرداری اسپکت میوکارد با استفاده از مدلسازی منحنی چند جمله ای
Authors
Abstract:
Background and purpose: Patient motion during myocardial perfusion SPECT can produce artifacts in reconstructed images which might affect clinical diagnosis. This paper attempts to present a new approach for the detection and correction of cardiac motion utilizing the data obtained during the imaging process. Materials and methods: Our method quantifies motion through polynomial curves modeling onto the 1D vectors corresponding to image frames obtained in summed profiles. To evaluate our method, physical sources and NCAT phantom were intentionally moved 1, 2 and 3 pixels at early, mid and late stages of data acquisition. The full width at half maximum (FWHM) values, the maximum count in the reconstructed image of physical sources, and maximum count in the myocardial wall in 360o view from cardiac perspective were compared with motion-free condition before and after motion correction. Results: Depending on the amount of motion and time of motion occurrence, the FWHM of point source changed from 5.56% to 37.49% compared to the motion-free condition while the relative change of FWHM for these sources changed from 0.8% to 1.84% after correction. The observed changes for maximum count in reconstructed images of point sources were from 1.91% - 21.33% which decreased to 0.13%-0.76% after motion correction. The corresponding changes for extended sources were 1.09%- 21.76% which reduced to 0.06%-0.45% after applying motion correction. In addition, the results showed that the distribution of radioactivity in the cardiac wall for the corrected image are very similar to the real values while the same values in the reconstructed image significantly differed from the original in which motion occurred during imaging. Conclusion: Our method detected and corrected cardiac motion during SPECT imaging through curve fitting of a polynomial onto the 1D vector values corresponding to image frames. Therefore, image misinterpretation can be avoided by correcting motion artifacts.
similar resources
اصلاح حرکت در تصویربرداری اسپکت میوکارد با استفاده از مدل سازی منحنی چند جمله ای
سابقه و هدف: حرکت بیمار طی تصویربرداری اسپکت پرفیوژن میوکارد می تواند باعث بروز آرتیفکت در تصاویر بازسازی شده شود و به نوبه خود می تواند روی تشخیص کلینیکی تأثیر بگذارد. هدف این تحقیق ارائه روشی برای تشخیص و تصحیح حرکت قلب با استفاده از داده های حاصل از سیستم تصویربرداری است. مواد و روش ها: کمی سازی حرکت قلب با استفاده از مدل سازی منحنی های چند جمله ای بر بردارهای یک بعدی متناظر با فریم های تصوی...
full textاثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین
Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...
full textاثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین
Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...
full textکاهش مرتبهی سیستم با استفاده از چند جمله ای های لاگر و الگوریتم جستجوی هارمونی
این مقاله، به ارائهی رهیافتی جهت کاهش مرتبهی سیستم ها ، مبتنی بر چند جملهای متعامد لاگر و الگوریتم جستجوی هارمونی می پردازد. به همین منظور، ساختار ثابت مناسبی برای مدل مرتبه کاهشی در نظر گرفته می شود. سپس با استفاده از الگوریتم جستجوی هارمونی با کمینه کردن یک تابع برازش، پارامتر های مدل مرتبه کاهشی به طور همزمان تعیین می شوند که تابع برازش، اختلاف میان l ضریب اول بسط لاگر مدل مرتبه کامل و l ...
full textحل عددی مدل کسری آلوده شدن سلول های CD4+T با استفاده از چند جمله ای های دیکسون
This paper presents a numerical method for solving a fractional model of HIV infection of CD4 + T cells. Using this model, we can examine the progression and spread of HIV. This method is a collocation method based on Dikson polynomials. Chebyshev's nodes are used in this method. By performing this process, the system of fractional differential equations converted to a nonlinear equations syst...
full textMy Resources
Journal title
volume 22 issue 96
pages 9- 20
publication date 2013-01
By following a journal you will be notified via email when a new issue of this journal is published.
No Keywords
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023