evaluation of effective sources in uncertainty measurements of personal dosimetry by a harshaw tld system

Authors

sm hosseini pooya iran nuclear regulatory authority, tehran, iran

t orouji iran nuclear regulatory authority, tehran, iran

abstract

background: the accurate results of the individual doses in personal dosimety which are reported by the service providers in personal dosimetry are very important. there are national / international criteria for acceptable dosimetry system performance. objective: in this research, the sources of uncertainties are identified, measured and calculated in a personal dosimetry system by tld. method: these sources are included; inhomogeneity of tlds sensitivity, variabil- ity of tld readings due to limited sensitivity and background, energy dependence, directional dependence, non-linearity of the response, fading, dependent on ambient temperature / humidity and calibration errors, which may affect on the dose responses. some parameters which influence on the above sources of uncertainty are studied for harshaw tld-100 cards dosimeters as well as the hot gas harshaw 6600 tld reader system. results: the individual uncertainties of each sources was measured less than 6.7% in 68% confidence level. the total uncertainty was calculated 17.5% with 95% confi- dence level. conclusion: the tld-100 personal dosimeters as well as the harshaw tld-100 reader 6600 system show the total uncertainty value which is less than that of admis- sible value of 42% for personal dosimetry services.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Evaluation of Effective Sources in Uncertainty Measurements of Personal Dosimetry by a Harshaw TLD System

Background: The accurate results of the individual doses in personal dosimety which are reported by the service providers in personal dosimetry are very important. There are national / international criteria for acceptable dosimetry system performance.Objective: In this research, the sources of uncertainties are identified, measured and calculated in a personal dosimetry system by TLD.Method: T...

full text

Evaluation of Effective Sources in Uncertainty Measurements of Personal Dosimetry by a Harshaw TLD System

BACKGROUND The accurate results of the individual doses in personal dosimety which are reported by the service providers in personal dosimetry are very important. There are national / international criteria for acceptable dosimetry system performance. Objective : In this research, the sources of uncertainties are identified, measured and calculated in a personal dosimetry system by TLD. METHO...

full text

investigation of effective parameters on the rigidity of light composite diaphragms (psscb) by fem

در این رساله با معرفی سقف های psscb متشکل از ترکیب ورق های فولادی ذوزنقه ای و تخته های سیمانی الیافی به عنوان سقف های پیش ساخته (سازگار با سیستم سازه ای قاب های فولادی سبک) به بررسی پارامترهای موثر بر صلبیت سقف، پرداخته می شود. در تحقیق حاضر ابتدا به مدل سازی دو نمونه سقف آزمایش شده، به روش اجزاء محدود با استفاده از نرم افزار تحلیلی abaqus ver 6.10 پرداخته شده است. نمونه های ساخته شده تحت اعما...

evaluation of sadr eminence in safavid period

چکیده: یکی از دوره های مهم تاریخی ایران به لحاظ تأمین استقلال ملی مذهبی و حتی تأثیر آن بر فرهنگ و مذهب ایرانیان، دوره صفویه است. رسمیت دادن و رواج مذهب شیعه توسط شاه اسماعیل اول، یکی از مهمترین اقدامات این دولت محسوب می شود. بنابراین برای اجرای این سیاست، وی منصب صدارت را به عنوان منصبی مذهبی- حکو متی ایجاد کرد .این منصب از دوره ی تیموریان ایجاد شده بود ولی در اواخر این دوره اهمیت بیشتری یافت...

15 صفحه اول

My Resources

Save resource for easier access later


Journal title:
journal of biomedical physics and engineering

جلد ۴، شماره ۲ Jun، صفحات ۰-۰