a monte carlo study for photoneutron dose estimations around the high-energy linacs

Authors

n mohammadi

s h miri-hakimabad

l rafat-motavalli

abstract

background: high-energy linear accelerator (linac) is a valuable tool and the most commonly device for external beam radiation treatments in cancer patients. in the linac head, high-energy photons with energies above the threshold of interaction produce photoneutrons. these photoneutrons deliver the extra dose to the patients in the planning treatment and increase the risk of secondary cancer. objective: in this study, a simplified model of the linac head was simulated and photoneutron dose equivalent was calculated at the isocenter and maze in the sphere detector. in addition, the absorbed and equivalent dose of photoneutron were estimated in the some organs of the phantom. methods: the simulations were made using the monte carlo code. the icrp reference adult male voxel phantom was used as the human body model for dosimetry calculations. results: the results of dose calculations in the isocenter and maze showed that photoneutron dose decreases as the function of distance from the isocenter and increases with increasing the distance from the entrance maze. conclusion: it is concluded that the simplified model of linac head is a useful and reliable method in dosimetry calculations. calculations illustrated that the photoneutron dose is not negligible and duo to its harmful biological effects on body, it should be considered in the treatment plans.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

A Monte Carlo Study for Photoneutron Dose Estimations around the High-Energy Linacs

Background: High-energy linear accelerator (linac) is a valuable tool and the most commonly device for external beam radiation treatments in cancer patients. In the linac head, high-energy photons with energies above the threshold of interaction produce photoneutrons. These photoneutrons deliver the extra dose to the patients in the planning treatment and increase the risk of secondary cancer.O...

full text

A Monte Carlo Study for Photoneutron Dose Estimations around the High-Energy Linacs

BACKGROUND High-energy linear accelerator (linac) is a valuable tool and the most commonly used device for external beam radiation treatments in cancer patients. In the linac head, high-energy photons with energies above the threshold of (γ,n) interaction produce photoneutrons. These photoneutrons deliver the extra dose to the patients undergoing radiation treatment and increase the risk of sec...

full text

A Monte Carlo study on Photoneutron Spectrum around Elekta SL75/25 18 MV linear accelerator

Medical linear accelerators are one of the most widespread methods for cancer treatment. Despite their advantages, unwanted photoneutrons are produced by high energy linacs. This photoneutrons are as undesired doses to patients and a significant problem for radiation protection of the staffs and patients. Photoneutrons radiological risk must be evaluated because of their high LET and range.in o...

full text

A Monte Carlo study on Photoneutron Spectrum around Elekta SL75/25 18 MV linear accelerator

Medical linear accelerators are one of the most widespread methods for cancer treatment. Despite their advantages, unwanted photoneutrons are produced by high energy linacs. This photoneutrons are as undesired doses to patients and a significant problem for radiation protection of the staffs and patients. Photoneutrons radiological risk must be evaluated because of their high LET and range.in o...

full text

a monte carlo study on photoneutron spectrum around elekta sl75/25 18 mv linear accelerator

medical linear accelerators are one of the most widespread methods for cancer treatment. despite their advantages, unwanted photoneutrons are produced by high energy linacs. this photoneutrons are as undesired doses to patients and a significant problem for radiation protection of the staffs and patients. photoneutrons radiological risk must be evaluated because of their high let and range.in o...

full text

Evaluation of the effective dose during PBFT for brain cancer: A Monte Carlo Study

Introduction: Recently, an approach exploiting the proton therapy biological enhancement by using Boron atoms injected inside a tumor, has been proposed. Three alpha particles with an average energy around 4MeV are emitted from the point of reaction between a proton and boron. In addition, the 719 keV prompt gamma emitted by the proton Boron fusion reactions can be used for on-...

full text

My Resources

Save resource for easier access later


Journal title:
journal of biomedical physics and engineering

جلد ۴، شماره ۴ DEC، صفحات ۰-۰

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023