simultaneous voltammetric determination of ascorbic acid and uric acid using a modified multiwalled carbon nanotube paste electrode

Authors

hadi beitollahit

hassan karimi-maleh

iran sheikhshoaie

abstract

this paper describes the development, electrochemical characterization and utilization of novel modified molybdenum (vi) complex-carbon nanotube paste electrode for the electrocatalytic determination of ascorbic acid (aa). the electrochemical profile of the proposed modified electrode was analyzed by cyclic voltammetry (cv) that showed a shift of the oxidation peak potential of aa about 235 mv to less positive value, compared with an unmodified carbon paste electrode. differential pulse voltammetry (dpv) in 0.1 m phosphate buffer solution (pbs) at ph 7.0 was performed to determine aa in the range of 0.1 to 950.0 μm, with a detection limit of 89.0 nm. then the modified electrode was used to determine aa in an excess of uric acid (ua) by dpv. finally, this method was used for the determination of aa in some real samples.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Simultaneous Voltammetric Determination of Ascorbic Acid and Uric Acid Using a Modified Multiwalled Carbon Nanotube Paste Electrode

This paper describes the development, electrochemical characterization and utilization of novel modified molybdenum (VI) complex-carbon nanotube paste electrode for the electrocatalytic determination of ascorbic acid (AA). The electrochemical profile of the proposed modified electrode was analyzed by cyclic voltammetry (CV) that showed a shift of the oxidation peak potential of AA about 235 mV ...

full text

Simultaneous Determination of Ascorbic Acid, Uric Acid and Tryptophan by Novel Carbon Nanotube Paste Electrode

In the present paper, electrochemical methods were used to investigate the behavior of ascorbic acid at a carbon paste electrode modified with 2,2'-((1E)-(1,2 phenylenebis(azanylylidene)) bis(methanylylidene))bis(benzene-1,4-diol) (PBD) and oxidized multiwall carbon nanotubes. The modified carbon paste electrode showed high electrocatalytic activity toward ascorbic acid; the current was enhance...

full text

Simultaneous Determination of Ascorbic Acid, Uric Acid and Tryptophan by Novel Carbon Nanotube Paste Electrode

In the present paper, electrochemical methods were used to investigate the behavior of ascorbic acid at a carbon paste electrode modified with 2,2'-((1E)-(1,2 phenylenebis(azanylylidene)) bis(methanylylidene))bis(benzene-1,4-diol) (PBD) and oxidized multiwall carbon nanotubes. The modified carbon paste electrode showed high electrocatalytic activity toward ascorbic acid; the current was enhance...

full text

Simultaneous Voltammetric Measurement of Ascorbic Acid, Epinephrine, Uric Acid and Tyrosine at a Glassy Carbon Electrode Modified with Nanozeolite-Multiwall Carbon Nanotube

In this study, incorporation of iron ion-doped natrolite nanozeolite, multi-wall carbon nanotubes into chitosan-coated glassy carbon electrode for the simultaneous determination of ascorbic acid, epinephrine, uric acid and tyrosine is studied. The results show that the combination of multi-wall carbon nanotubes and iron ion-doped natrolite zeolite causes a dramatic enhancement in the sensitivit...

full text

Simultaneous voltammetric determination of norepinephrine, ascorbic acid and uric acid on polycalconcarboxylic acid modified glassy carbon electrode.

A novel polycalconcarboxylic acid (CCA) modified glassy carbon electrode (GCE) was fabricated by electropolymerization and then successfully used to simultaneously determine ascorbic acid (AA), norepinephrine (NE) and uric acid (UA). The characterization of electrochemically synthesized Poly-CCA film was investigated by atomic force microscopy (AFM), electrochemical impedance spectroscopy (EIS)...

full text

Electrochemical Sensor for Determination of Ascorbic Acid Using a 2-Chlorobenzoyl Ferrocene/Carbon Nanotube Paste Electrode

A chemically modified carbon paste electrode with 2-chlorobenzoyl ferrocene (2CBF) and carbon nanotube (2CBFCNPE) was employed to study the electrocatalytic oxidation of ascorbic acid in aqueous solution using cyclic voltammetry, square wave voltammetry and chronoamperometry. The diffusion coefficient (D = 1.42 × 10-6 cm2 s-1), and the kinetic parameter such as ...

full text

My Resources

Save resource for easier access later


Journal title:
caspian journal of chemistry

Publisher: university of mazandaran

ISSN 1735-0611

volume 1

issue 1 2012

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023