optimizing of the tangential technique and supraclavicular fields in 3 dimensional conformal radiation therapy for breast cancer

Authors

dr keyvan jabbari

nazli azarmahd

dr shadi babazadeh

dr alireza amouheidari

abstract

radiotherapy plays an essential role in the management of breast cancer. three-dimensional conformal radiation therapy (3d-crt) is applied based on 3d image information of anatomy of patients. in three-dimensional conformal radiation therapy (3d-crt) for breast cancer one of the common techniques is tangential technique. in this project, various parameters of tangential and supraclavicular fields are optimized. this project has been done on ct images of 100 patients in isfahan milad hospital. all patients have been simulated and all the important organs have been contoured by radiation oncologist. two techniques in supraclavicular region are evaluated including: 1- a single field (ap anterior posterior) with a dose of 200cgy per fraction with 6mv energy. this is a common technique. 2- two parallel opposed fields (anterior posterior-posterior anterior).  the dose of ap was 150cgy with 6mv energy and pa 50cgy with 18mv. in the second part of the project, the tangential fields has been optimized with change of normalization point in five points: 1- iso center (confluence of rotation gantry axis and collimator axis) 2- middle of thickest part of breast or middle of inter field distance (ifd) 3- border between lung and chest wall 4- physician’s choice 5- between ifd and isocenter. dose distributions have been compared for all patients in different methods of   supraclavicular and tangential field. in parallel opposed fields average lung dose was 4% more than single field and the maximum received heart dose was 21.5% less than single field. the average dose of ptv (planning tumor volume) in method 2 is 2 % more than method 1.  in general ap-pa method because of a better coverage of ptv is suggested. in optimization of the tangential field all methods have similar coverage of ptv. each method has spatial advantages and disadvantages. if it is important for the physician to reduce the dose received by the lung and heart, fifth  method is suggested since in this method average and maximum received dose to heart and lung  have been reduced few percent in comparison to other methods. if a better coverage of ptv is important for the physician second method can be an optimized method. in this method average and maximum received dose to ptv have been increased few percent in comparisons of physician’s choice method and three other methods. in optimizing of supraclavicular field ap-pa method due to better coverage of ptv is suggested. in optimizing of tangential all methods are similar. each method has special advantages and disadvantages. the physicians can change the depth of the normalization point in the breast to get the desired average dose.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Optimizing of the Tangential Technique and Supraclavicular Fields in 3 Dimensional Conformal Radiation Therapy for Breast Cancer

Radiotherapy plays an essential role in the management of breast cancer. Three-dimensional conformal radiation therapy (3D-CRT) is applied based on 3D image information of anatomy of patients. In 3D-CRT for breast cancer one of the common techniques is tangential technique. In this project, various parameters of tangential and supraclavicular fields are optimized. This project has been done on ...

full text

Optimization of tangential fields arrangement in the breast cancer 3D conformal radiation therapy

Introduction: The incidence of breast cancer increases with the rate of 1-2% at the world. Radiation therapy is one of the available choices for breast cancer treatment. The single isocentre half-beam block technique is considered as a standard technique to avoid hot and cold spots within the PTV. The major advantage of half beam technique is that the both contralateral breast...

full text

Intensity modulated radiation therapy (IMRT) technique for left breast cancer by different numbers of beam fields

Background: Intensity Modulated Radiotherapy (IMRT) can improve radiotherapy (RT) results by improving healthy tissue sparing. Additionally, IMRT provides more consistent dose deliveries and suppresses secondary tumor formation. RT is a principal treatment in breast cancer (BC). Aim: To evaluate the outcome of the Radiotherapy Plans (RTP) that use IMRT technique to left breast and other organs,...

full text

Optimization of 3D Planning Dosimetry in a Breast Phantom for the Match Region of Supraclavicular and Tangential Fields

Introduction: The complex geometry of breast and also lung and heart inhomogeneities near the planning target volume (PTV) result in perturbations in dose distribution. This problem can result in overdosage or underdosage in the match region of the three treatment fields. The purpose of this study is to create a homogeneous dose distribution in the match region between the supraclavicular and t...

full text

Comparison of Radiobiological Models for Radiation Therapy Plans of Prostate Cancer: Three-dimensional Conformal versus Intensity Modulated Radiation Therapy

Purpose: In the current study, using different radiobiological models, tumor control probability (TCP) and normal tissue complication probability (NTCP) of radiotherapy plans were calculated for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) of prostate cancer.Methods and Materials: 10 prostate plans were randomly selected among patients ...

full text

the study of aaag repeat polymorphism in promoter of errg gene and its association with the risk of breast cancer in isfahan region

چکیده: سرطان پستان دومین عامل مرگ مرتبط با سرطان در خانم ها است. از آنجا که سرطان پستان یک تومور وابسته به هورمون است، می تواند توسط وضعیت هورمون های استروئیدی شامل استروژن و پروژسترون تنظیم شود. استروژن نقش مهمی در توسعه و پیشرفت سرطان پستان ایفا می کند و تاثیر خود را روی بیان ژن های هدف از طریق گیرنده های استروژن اعمال می کند. اما گروه دیگری از گیرنده های هسته ای به نام گیرنده های مرتبط به ا...

15 صفحه اول

My Resources

Save resource for easier access later


Journal title:
journal of medical signals and sensors

جلد ۳، شماره ۲، صفحات ۰-۰

Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023