reducing the respiratory motion artifacts in pet cardiology: a simulation study
Authors
abstract
introduction: there are several technical features that make pet an ideal device for the noninvasive evaluation of cardiac physiology. organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac pet imaging. these motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent lesion size and shape and reducing both signal and signal-to-noise ratio levels methods: 4d average male torso (2 cm diaphragmatic motion) produced by ncat phantom was used for simulations. emission sinograms generated by eidolon pet simulator were reconstructed using iterative algorithm using stir. the respiratory motion correction (rmc) applied to data sets using an automatic algorithm. cross section views, activity profiles, contrast-to-noise ratios and left ventricle myocardium widths of corrected and non-corrected images were compared to investigate the effect of applied correction. results: comparison of respiratory motion corrected and non corrected images showed that the algorithm properly restores the left ventricle myocardium width, activity profile and improves contrast-to-noise ratios in all cases. comparing the contrast recovery coefficient ( )shows that the applied correction effected phases of number 7,8 and 9 of cardiac cycle more than the other 13 phases and the maximum value being 1.43±0.07 for phase number 8. the maximum value of ratio of the left ventricle myocardium width for non-rmc and rmc images along the line profile passing the apicobasal direction and along the line profile passing from the middle of the lateral wall of the left ventricle were 1.38±0.07 for phase number 9 and 1.12±0.03 for phases of number 8 and 9 respectively. conclusion: blurring and ghosting of each image depends on the speed of diaphragm during that respiratory phase. this simulation study demonstrates that respiratory motion correction has good overall effect on pet cardiac images and can reduces errors originating from diaphragmatic motion and deformation. effect of such a correction varies from one cardiac phase to another and this depends on the blurring and ghosting of all respiratory phases used to form this cardiac phase. using an automatic algorithm capable of correcting respiratory motion using full signal may be very useful to prevent lengthening of the overall scan time to obtain same motionless lesion signal levels.
similar resources
Reducing the respiratory motion artifacts in PET cardiology: A simulation study
Introduction: There are several technical features that make PET an ideal device for the noninvasive evaluation of cardiac physiology. Organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac PET imaging. These motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent les...
full textThe influence of respiratory motion on dose distribution of 3D-CRT and IMRT- A simulation study
Background: 3DCRT (three-dimensional conformal radiotherapy) and IMRT (intensity-modulated radiotherapy) has provided us with tools to delineate the radiation dose distribution of tumor targets. However, the precision of radiation can be compromised by respiratory motion, which usually limits the geometric and dosimetric accuracy of radiotherapy. The purpose of this study is to evaluate the imp...
full text4D PET/CT as a Strategy to Reduce Respiratory Motion Artifacts in FDG-PET/CT
The improved accuracy in tumor identification with FDG-PET has led to its increased utilization in target volume delineation for radiotherapy treatment planning in the treatment of lung cancer. However, PET/CT has constantly been influenced by respiratory motion-related image degradation, which is especially prominent for small lung tumors in the peri-diaphragmatic regions of the thorax. Here, ...
full textRespiratory motion correction in prostate cancer positron emission tomography: A study on patients and phantom simulation
Introduction: To investigate the effects of breathing cycle and tree diaphragm motions on prostate cancer tumors standard uptake value (SUV) during positron emission tomography (PET) and to correct it. Materials and methods: Respiratory motion traces were simulated on the common patient breathing cycle and tree diaphragm motio...
full texta study on rate making and required reserves determination in reinsurance market: a simulation
reinsurance is widely recognized as an important instrument in the capital management of an insurance company as well as its risk management tool. this thesis is intended to determine premium rates for different types of reinsurance policies. also, given the fact that the reinsurance coverage of every company depends upon its reserves, so different types of reserves and the method of their calc...
Reducing respiratory motion artifacts in fast 2D dynamic contrast enhanced MRI in liver using structural similarity
Reducing respiratory motion artifacts in fast 2D dynamic contrast enhanced MRI in liver using structural similarity E.G.W. ter Voert, L. Heijmen, C.J.A. Punt, J.H.W. de Wilt, H.W.M. van Laarhoven, and A. Heerschap Radiology, Radboud University Medical Centre, Nijmegen, Gelderland, Netherlands, Medical Oncology, Radboud University Medical Centre, Nijmegen, Gelderland, Netherlands, Medical Oncolo...
full textMy Resources
Save resource for easier access later
Journal title:
iranian journal of nuclear medicinePublisher: tehran university of medical sciences
ISSN 1681-2824
volume 15
issue 2 2007
Keywords
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023