comparison between early and delayed images of 67ga scintigraphy for evaluation of recurrent lymphoma

Authors

toktam mohammadi rana

mohammad mahdi koushyar

abbas shirdel

vahid reza dabbagh kakhki

mehdi momennezhad

abstract

introduction: despite widespread use of 67gallium for lymphoma evaluation, timing of imaging after injection is a matter of controversy and to the extent of our knowledge no direct comparison has been made between early and delayed gallium images. we aimed to compare 24 and 48 hours post injection planar gallium imaging for evaluation of lymphoma recurrence. methods: 255 patients suspicious of recurrent lymphoma were included in the study. twenty four and 48 hours post injection (10 mci) whole body gallium imaging was performed. semi-quantitative evaluation (background corrected) was carried out in positive whole body 67gallium scans. diagnosis of recurrence was made by combination of clinical or pathologic examination if possible. in 59 patients the final diagnosis was made by tissue biopsy. in case of uncertain diagnosis, follow up of the patients (mean duration of 13 months) was used. the diagnosis was finally made by the referring hematologist. results: whole body gallium scintigraphy was positive in 115 out of 150 patients with recurrence (sensitivity of 76%). comparison of the 24 and 48 hour images did not show any new lesion in the 48 hour images. however, delayed 48 hours images were required for definite detection of the gallium avid lesions in the abdominal and pelvic areas in 40 patients. semi-quantitative evaluation of the lesions showed higher lesion to background ratio for 48 compared to the 24 hour images (p

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Comparison between early and delayed images of 67Ga scintigraphy for evaluation of recurrent lymphoma

Introduction: Despite widespread use of 67Gallium for lymphoma evaluation, timing of imaging after injection is a matter of controversy and to the extent of our knowledge no direct comparison has been made between early and delayed gallium images. We aimed to compare 24 and 48 hours post injection planar gallium imaging for evaluation of lymphoma recurrence. Methods: 255 pa...

full text

Sensitivity of gallium scintigraphy for evaluation of recurrent lymphoma: Comparison of planar and SPECT imaging

  Introduction: Although PET scanning using F-18[FDG] is considered the superior radiotracer for tumnor imaging, Gallium-67 is still in use for some malignancies such as lymphoma and hepatoma. One of the strategies to improve the diagnostic accuracy of Gallium is to perform SPECT which is reported to be more sensitive compared to planar imaging. In this study we compa...

full text

sensitivity of gallium scintigraphy for evaluation of recurrent lymphoma: comparison of planar and spect imaging

introduction: although pet scanning using f-18[fdg] is considered the superior radiotracer for tumnor imaging, gallium-67 is still in use for some malignancies such as lymphoma and hepatoma. one of the strategies to improve the diagnostic accuracy of gallium is to perform spect which is reported to be more sensitive compared to planar imaging. in this study we compared the sensitivity of spect ...

full text

the evaluation and comparison of two esp textbooks available on the iranian market for teaching english to the students of medicine

abstract this study evaluated and compared medical terminology and english for the students of medicine (ii) as two representatives of the textbooks available on the iranian market for teaching english to the students of medicine. this research was performed on the basis of a teacher’s and a number of students’ attitudes and the students’ needs analysis for two reasons: first, to investigate...

15 صفحه اول

Early 67Ga scintigraphy for the localization of abnominal abscesses.

Sixty patients suspected of having abdominal abscesses were evaluated by early and delayed 67Ga scintigraphy. The 67Ga scintigraphs obtained 6 hr after injection correctly localized 18 of 20 abdominal or retroperitoneal abscesses. An additional 13 patients with abnormal scintigraphs had clinically established infections. In no instance was an abscess or inflammatory focus present on delayed sci...