rapid high performance liquid chromatographic method for determination of clarithromycin in human plasma using amperometric detection: application in pharmacokinetic and bioequivalence studies

Authors

seyed mohsen foroutan 1- department of pharmaceutics, school of pharmacy, shahid beheshti university of medical sciences, tehran, iran. 2- pharmaceutical sciences research center, shahid beheshti university of medical sciences, tehran, iran.

afshin zarghi 1- department of pharmaceutical chemistry, school of pharmacy, shahid beheshti university of medical sciences, tehran, iran. 2- pharmaceutical sciences research center, shahid beheshti university of medical sciences, tehran, iran.

alireza shafaati 1- department of pharmaceutical chemistry, school of pharmacy, shahid beheshti university of medical sciences, tehran, iran. 2- pharmaceutical sciences research center, shahid beheshti university of medical sciences, tehran, iran.

babak madadadian noor research and educational institute, tehran, iran.

abstract

a rapid, sensitive and reproducible hplc method using amperometric detector was developed and validated for the analysis of clarithromycin in human plasma. the separation was achieved on a monolithic silica column (mz- c8 125×4.0 mm) using acetonitrile- methanol-potassium dihydrogen phosphate buffer (40:6:54,v/v), with ph of 7.5, as the mobile phase at a flow rate of 1.5 ml/min. the assay enables the measurement of clarithromycin for therapeutic drug monitoring with a minimum quantification limit of 20 ng/ml. the method involves simple, protein precipitation procedure and analytical recovery was complete. the calibration curve was linear over the concentration range of 0.1-6 µg/ml. the coefficients of variation for inter-day and intra-day assay were found to be less than 6%. this method was used in bioequivalency and pharmacokinetic studies of the test (generic) product 2 × 500 mg clarithromycin tablets, with respect to the reference product.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Rapid High Performance Liquid Chromatographic Method for Determination of Clarithromycin in Human Plasma Using Amperometric Detection: Application in Pharmacokinetic and Bioequivalence Studies

A rapid, sensitive and reproducible HPLC method using amperometric detector was developed and validated for the analysis of clarithromycin in human plasma. The separation was achieved on a monolithic silica column (MZ- C8 125×4.0 mm) using acetonitrile- methanol-potassium dihydrogen phosphate buffer (40:6:54,v/v), with pH of 7.5, as the mobile phase at a flow rate of 1.5 mL/min. The assay enabl...

full text

Rapid High Performance Liquid Chromatographic Method for Determination of Clarithromycin in Human Plasma Using Amperometric Detection: Application in Pharmacokinetic and Bioequivalence Studies

A rapid, sensitive and reproducible HPLC method using amperometric detector was developed and validated for the analysis of clarithromycin in human plasma. The separation was achieved on a monolithic silica column (MZ- C8 125×4.0 mm) using acetonitrile- methanol-potassium dihydrogen phosphate buffer (40:6:54,v/v), with pH of 7.5, as the mobile phase at a flow rate of 1.5 mL/min. The assay enabl...

full text

High-Performance Liquid Chromatographic Determination of Rivastig-mine in Human Plasma for Application in Pharmacokinetic Studies

A simple and reproducible HPLC method with spectrophotometric detection was developed for determination of rivastigmine in human plasma. Liquid-liquid extraction of rivastigmine and donepezil (as internal standard) from plasma samples was performed with 1-butanol/n-hexane (2:98 v/v) in alkaline condition followed by back-extraction into diluted acetic acid. Chromatography was carried out using ...

full text

High-Performance Liquid Chromatographic Determination of Rivastig-mine in Human Plasma for Application in Pharmacokinetic Studies

A simple and reproducible HPLC method with spectrophotometric detection was developed for determination of rivastigmine in human plasma. Liquid-liquid extraction of rivastigmine and donepezil (as internal standard) from plasma samples was performed with 1-butanol/n-hexane (2:98 v/v) in alkaline condition followed by back-extraction into diluted acetic acid. Chromatography was carried out using ...

full text

Rapid High Performance Liquid Chromatographic Method for Determination of Clarithromycin in Human Plasma Using Amperometric Detection: Application in Pharmacokinetic and Bioequivalence Studies

A rapid, sensitive and reproducible HPLC method using amperometric detector was developed and validated for the analysis of clarithromycin in human plasma. The separation was achieved on a monolithic silica column (MZ- C8 125×4.0 mm) using acetonitrile-methanol-potassium dihydrogen phosphate buffer (40:6:54,v/v), with pH of 7.5, as the mobile phase at a flow rate of 1.5 mL/min. The assay enable...

full text

high-performance liquid chromatographic determination of rivastig-mine in human plasma for application in pharmacokinetic studies

a simple and reproducible hplc method with spectrophotometric detection was developed for determination of rivastigmine in human plasma. liquid-liquid extraction of rivastigmine and donepezil (as internal standard) from plasma samples was performed with 1-butanol/n-hexane (2:98 v/v) in alkaline condition followed by back-extraction into diluted acetic acid. chromatography was carried out using ...

full text

My Resources

Save resource for easier access later


Journal title:
the iranian journal of pharmaceutical research

جلد ۱۲، شماره Supplement، صفحات ۶۵-۶۹

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023