electrochemical evaluation of hydroxyapatite/zrn coated magnesium biodegradable alloy in ringer solution as a simulated body fluid

Authors

seyed rahim kiahosseini department of materials engineering, science and research branch, islamic azad university, tehran, iran

abdollah afshar department of materials engineering, sharif university of technology, tehran, iran

majid mojtahedzadeh larijani agriculture medical and industrial research school, nuclear science and technology research institute (nstri), karaj, iran

mardali yousefpour department of materials science and engineering, semnan university, semnan, iran

abstract

magnesium alloys as biodegradable materials can be used in body as an implant materials but since they have poor corrosion resistance, it is required to decrease their corrosion rate by biocompatible coatings. in this study, hydroxyapatite (ha) coatings in the presence of an intermediate layer of zrn as a biocompatible material, deposited on az91 magnesium alloy by ion beam sputtering method at 300 °c temperature and at different times 180, 240, 300, 360 and 420 min. then changes in corrosion resistance of samples in ringer's solution as a solution similar to the human body was evaluated in two ways, potentiodynamic polarization and electrochemical impedance spectroscopy (eis). to investigate the causes of the destruction of the samples, the surface of samples was studied by scanning electron microscopy (sem). the results showed that because of porous coatings created, the corrosion potential of the samples was about +55mv higher than the uncoated substrate that by changing the deposition time, was not observed the significant change but with increasing deposition time to 360 min, corrosion current decreased which represents an increase of corrosion resistance of magnesium alloy in body solution. however, a further increase in deposition time to 420 min, due to increase thickness and stress in the layer, the corrosion resistance of the samples was reduced. the results of the eis confirm the corrosion behavior of the polarization method, too.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Influence of circumferential notch and fatigue crack on the mechanical integrity of biodegradable magnesium-based alloy in simulated body fluid.

Applications of magnesium alloys as biodegradable orthopaedic implants are critically dependent on the mechanical integrity of the implant during service. In this study, the mechanical integrity of an AZ91 magnesium alloy was studied using a constant extension rate tensile (CERT) method. The samples in two different geometries that is, circumferentially notched (CN), and circumferentially notch...

full text

In Vitro Corrosion Study of Friction Stir Processed WE43 Magnesium Alloy in a Simulated Body Fluid

Corrosion behavior of friction stir processing (FSP) WE43 alloy in a simulated body fluid (SBF) was investigated. Micro-galvanic corrosion was the dominated corrosion behavior, and the corrosion resistance of FSP WE43 alloy was improved compared to the cast counterpart. Furthermore, due to the fine-grained and homogeneous microstructure, uniform corrosion morphology was observed on FSP WE43 all...

full text

Electrochemical Corrosion and In Vitro Bioactivity of Nano-Grained Biomedical Ti-20Nb-13Zr Alloy in a Simulated Body Fluid

The bioactivity and the corrosion protection for a novel nano-grained Ti-20Nb-13Zr at % alloy were examined in a simulated body fluid (SBF). The effect of the SPS's temperature on the corrosion performance was investigated. The phases and microstructural details of the developed alloy were analyzed by XRD (X-ray Diffraction), SEM (Scanning Electron Microscopy), and TEM (Transmission Electron Mi...

full text

Corrosion resistance and cytocompatibility of biodegradable surgical magnesium alloy coated with hydrogenated amorphous silicon.

The fast degradation rates in the physiological environment constitute the main limitation for the applications of surgical magnesium alloys as biodegradable hard-tissue implants. In this work, a stable and dense hydrogenated amorphous silicon coating (a-Si:H) with desirable bioactivity is deposited on AZ91 magnesium alloy using magnetron sputtering deposition. Raman spectroscopy and Fourier tr...

full text

Biocompatibility of magnesium-zinc alloy in biodegradable orthopedic implants.

In this study, magnesium-zinc (Mg-Zn) alloy was investigated as a biodegradable orthopedic implant. MC3T3-E1 cell attachment, mineralization and osteogenic-specific mRNA expression were assessed for as measurements of the in vitro biocompatibility of Mg-Zn alloy. In vivo degradation of the Mg-Zn alloy and the accompanying new bone formation in the femoral marrow cavity were analyzed by scanning...

full text

Effect of TiO2 nano-particles on corrosion behavior of Co-Cr alloy coatings in simulated body fluid

Co-Cr and Co-Cr/nano-TiO2 coatings were electrodeposited from Cr(III) based baths. The effect of TiO2 nano-particles incorporation on the morphology, structure, crystallite size, and preferred orientation was studied. Corrosion behavior of the composite coating was also investigated by means of polarization and electrochemical impedance spectroscopy techniques in Hanks’ si...

full text

My Resources

Save resource for easier access later


Journal title:
journal of chemical health risks

جلد ۵، شماره ۱، صفحات ۰-۰

Hosted on Doprax cloud platform doprax.com