resonance frequency analysis of implant stability in augmented and non-augmented sinus sites

Authors

amir moeintaghavi 1professor. oral and maxillofacial diseases research center, school of dentistry, mashhad university of medical sciences, mashhad, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (mashhad university of medical sciences)

habibollah ghanbari 1professor. oral and maxillofacial diseases research center, school of dentistry, mashhad university of medical sciences, mashhad, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (mashhad university of medical sciences)

mehrdad radvar dental research center, school of dentistry, mashhad university, medical sciences, mashhad, iran

naser sargolzaei dental materials research center, school of dentistry, mashhad university of medical sciences, mashhad, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (mashhad university of medical sciences)

abstract

background and aim:  although there have been substantial developments in dental implant therapies, achieving good implant stability (isq >60) for implants inserted in augmented sinus sites appears to be challenging in comparison with non-augmented sites due to the high prevalence of bone resorption in posterior regions of maxilla. this study aimed to evaluate and compare the time required to achieve good implant stability between implants inserted in sites that had undergone a sinus augmentation procedure with implants inserted in non-augmented similar regions of maxilla. methods: thirty stroman iti dental implants were inserted in 14 patients (8 females and 6 males) with average age of 55 ± 10 years. fourteen implants were inserted in sinus augmented sites (open sinus elevation and demineralized freezed bone allograft  or dfdba) 6 months after healing (test group), and 16 implants were inserted into non-augmented  posterior areas of maxilla (control group). the implant stability quotient (isq) for each implant was measured at the time of insertion (baseline, isq0) and at 1, 2 and 3 months later (isq1, isq2, isq3). residual and augmented bone heights were also recorded. results: the average residual bone height was 2.92 ± 0.63mm and 10.41 ± 1.46mm for the augmented bone height. the difference between isq values in the test and control groups was only significant at the baseline (p=0.023). no significant correlation was found between isq and bone height (residual and augmented), and there was no significant correlation between isq values and the implant diameter and length. in the test group, the differences between isq0 and isq1, isq1 and isq3 and isq2 and isq3 were all statistically significant (p=0.006, p=0.032, p=0.046). in the control group, the difference was only significant between isq0 and isq1 (p=0.002). conclusion:  isq values were not statistically significant between implants inserted in natural and augmented bone six months after sinus augmentation. in other words, within the limitation of this study, the time required to achieve good stability for implants inserted in augmented sinus sites is similar to those inserted in non-augmented sites.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Resonance frequency analysis of implant stability in augmented and non-augmented sinus sites

Background and aim:  Although there have been substantial developments in dental implant therapies, achieving good implant stability (ISQ >60) for implants inserted in augmented sinus sites appears to be challenging in comparison with non-augmented sites due to the high prevalence of bone resorption in posterior regions of maxilla. This study aimed to evaluate and compare the time required to a...

full text

resonance frequency analysis of clinical stability of astra tech and iti implant systems

background and aims. resonance frequency analysis (rfa) offers a noninvasive clinical measurement of stability and osseointegration of implants; it is a useful tool to establish implant loading time. the rfa values are represented by a quantitative unit called the implant stability quotient (isq) on a scale from 1 to 100. the aim of the present study was to measure the stability of astra tech a...

full text

RESONANCE FREQUENCY ANALYSIS FOR IMPLANT STABILITY MEASUREMENTS. A review

The resonance frequency analysis (RFA) technique for implant stability measurements was developed by Meredith and coworkers more than 20 years ago. RFA makes use of a transducer (peg), which is attached to the implant and excited over a range of frequencies by electro-magnetic waves to measure the resonance frequency (RF) of the transducer. The underlying RF measurements in Hz are translated to...

full text

Augmented Reality Assisted Sinus Surgery

In this paper, we propose an augmented reality (AR) assisted sinus surgery system, in which the surgical outcome is improved by providing a new way of visualization which embeds virtual environments into the real scene. Such an AR assisted system, with a preoperative CT scan registered and displayed throughout the surgery, would provide the surgeon visibility of the nearby structures surroundin...

full text

Biomechanical analysis of influence of implant configuration and bone quality on implant stability in augmented posterior maxilla

The present study applied FE methods to evaluate the biomechanical effects induced by implant configuration and bone quality within an augmented posterior maxilla. The aim of this study was to ascertain the optimal choice of implant on the basis of actual bone conditions. A couple of simplified maxillary segment models vary in bone quality (D2, D3 and D4 type) were constructed. Imlants were emb...

full text

My Resources

Save resource for easier access later


Journal title:
journal of dental materials and techniques

جلد ۵، شماره ۱، صفحات ۴۳-۴۸

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023