Contamination: a comparison of 2 personal protective systems.

نویسندگان

  • Jorge E Zamora
  • John Murdoch
  • Brian Simchison
  • Andrew G Day
چکیده

BACKGROUND The purpose of this study was to examine the difference in self-contamination rates and levels of contact and droplet protection associated with enhanced respiratory and contact precautions (E-RCP) and a personal protective system that included a full body suit, personal protective equipment and a powered air-purifying respirator (PAPR). METHODS In this prospective, randomized, controlled crossover study, 50 participants donned and removed E-RCP and PAPR in random order. Surrogate contamination consisted of fluorescein solution and ultraviolet (UV) light- detectable paste, which was applied after each ensemble was donned. A blinded evaluator inspected participants for contamination using a UV lamp after removal of each ensemble. Areas of contamination were counted and measured in square centimetres. Donning and removal violations were recorded. The primary end point was the presence of any contamination on the skin or base clothing layer. RESULTS Participants wearing E-RCP were more likely to experience skin and base-clothing contamination; their contamination episodes measuring > or = 1 cm2 were more frequent, and they had larger total areas of contamination (all p < 0.0001). The anterior neck, forearms, wrists and hands were the likeliest zones for contamination. Participants donning PAPR committed more donning procedure violations (p = 0.0034). Donning and removing the PAPR system took longer than donning and removing E-RCP garments (p < 0.0001). INTERPRETATION Participants wearing E-RCP were more likely to experience contamination of their skin and base clothing layer. Those wearing PAPR required significantly more time to don and remove the ensemble and violated donning procedures more frequently.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ebola virus disease: The use of fluorescents as markers of contamination for personal protective equipment

The recent Ebola virus disease (EVD) outbreak has created interest in personal protective equipment (PPE) content and usage. PPE testing has historically been done by individual component, rather than as a bundle for contact isolation. Fluorescent agents are commonly used in training for infection control techniques. The purpose of our study was to compare 2 PPE bundles and to evaluate the feas...

متن کامل

Virus Transfer from Personal Protective Equipment to Healthcare Employees’ Skin and Clothing

We evaluated a personal protective equipment removal protocol designed to minimize wearer contamination with pathogens. Following this protocol often resulted in virus transfer to hands and clothing. An altered protocol or other measures are needed to prevent healthcare worker contamination.

متن کامل

Qualitative assessment of isocyanate skin exposure in auto body shops: a pilot study.

BACKGROUND Little is known about the extent of human isocyanate skin exposure in auto body shops and the effectiveness of personal protective equipment. Animal studies have suggested that skin exposure to isocyanates may be an important risk factor for respiratory sensitization leading to asthma. This study provides initial data on hexamethylene diisocyanate skin exposure in three auto body sho...

متن کامل

Contamination during doffing of personal protective equipment by healthcare providers

OBJECTIVE In this study, we aimed to describe the processes of both the donning and the doffing of personal protective equipment for Ebola and evaluate contamination during the doffing process. METHODS We recruited study participants among physicians and nurses of the emergency department of Samsung Medical Center in Seoul, Korea. Participants were asked to carry out doffing and donning proce...

متن کامل

Influence of tracheal suctioning systems on health care workers' gloves and equipment contamination: a comparison of closed and open systems.

The impact of tracheal suctioning with an open or a closed system on equipment and health care workers contamination with multidrug-resistant pathogens was compared. Only the closed system reduced hand and equipment contamination during tracheal suctioning. This equipment could be systematically used to reduce risk of cross contamination in the intensive care unit.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • CMAJ : Canadian Medical Association journal = journal de l'Association medicale canadienne

دوره 175 3  شماره 

صفحات  -

تاریخ انتشار 2006