Evaluation of Mechanical Properties and Marginal Fit of Crowns Fabricated Using Commercially Pure Titanium and FUS-Invest

نویسندگان

  • Jinshuang Wu
  • Xianli Wang
  • Helin Xing
  • Tianwen Guo
  • Chaofang Dong
  • Sefei Yang
چکیده

This study investigated the mechanical properties and single crown accuracy of the tailor-made Fourth University Stomatology investment (FUS-invest) for casting titanium. Background. Current investment for casting titanium is not optimal for obtaining high-quality castings, and the commercially available titanium investment is costly. Methods. Titanium specimens were cast using the tailor-made FUS-invest. The mechanical properties were tested using a universal testing machine. Fractured castings were characterized by energy-dispersive spectroscopy. 19 titanium crowns were produced using FUS-invest and another 19 by Symbion. The accuracy of crowns was evaluated. Results. The mechanical properties of the titanium cast by FUS-invest were elastic modulus 125.6 ± 8.8 GPa, yield strength 567.5 ± 11.1 MPa, tensile strength 671.2 ± 15.6 MPa, and elongation 4.6 ± 0.2%. For marginal fit, no significant difference (P > 0.05) was found at four marker points of each group. For internal fit, no significant difference (P > 0.05) was found between two groups, whereas significant difference (P < 0.01) was found at different mark point of each group. Conclusions. The mechanical properties of titanium casted using FUS-invest fulfilled the ISO 9693 criteria. The marginal and internal fit of the titanium crowns using either the FUS-invest or Symbion were similar.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The influence of mold temperature on the fit of cast crowns with commercially pure titanium.

Commercially pure titanium (CP Ti) has been widely applied to fabricate cast devices because of its favorable properties. However, the mold temperature recommended for the manufacture of casts has been considered relatively low, causing inadequate castability and poor marginal fit of cast crowns. This study evaluated and compared the influence of mold temperature (430 degrees C--as control, 550...

متن کامل

Marginal and internal adaptation of commercially pure titanium and titanium-aluminum-vanadium alloy cast restorations.

AIM The purpose of this in vitro study was to investigate the marginal accuracy and internal fit of complete cast crowns and three-unit fixed partial dentures (FPDs) cast with commercially pure titanium (CPTi) and Titanium-Aluminum-Vanadium alloy (Ti-6Al-4V). METHODS AND MATERIALS CPTi and Ti-6Al-4V alloy were used to cast twelve single crowns and twelve three-unit FPDs. A traveling microscop...

متن کامل

مقایسه تطابق کراون‌های سرامیکی فلدسپاتیک تهیه شده از روی قالب سیلیکون افزایشی و کست گچی به وسیله دستگاه CAD-CAM

  Background and Aims: Marginal fit is one of the key factors in the success of fixed restoration. The aim of this study was to evaluate the fitness of feldespatic crowns made from additional silicon impression and gypsum cast by CAD/CAM.   Materials and Methods: 10 intact extracted upper premolar teeth were used for this experimental study. After preparation of the mounted teeth with radial sh...

متن کامل

Evaluation of hardness and wear resistance of nano-sized titanium-carbide-reinforced commercially cast aluminum alloy matrices

Production of aluminum matrix composites is widespread because these material provide enhanced mechanical properties compared to aluminum. One the most important parameters of metal matrix composite production is uniform distribution of reinforcing nanoparticles in matrices using the stir-casting method. Second is ensuring high wettability, which is determined by evaluating the properties of ma...

متن کامل

Numerical and Experimental Investigation of the Effect of Open-Die Hot Deep Drawing Process Parameters on the Formability of Commercially Pure Titanium

In the present study, the finite element analysis of the hot deep drawing process of commercially pure (CP) titanium has been performed without the blank holder in order to investigate the influence of temperature (T), die radius (Rd) and blank diameter (D) on the maximum punch force (Fp) and minimum thickness of the blank (t). Tensile tests were first conducted to extract...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2017  شماره 

صفحات  -

تاریخ انتشار 2017