Precise efficiency calibration of an HPGe detector: source measurements and Monte Carlo calculations with sub-percent precision.

نویسندگان

  • J C Hardy
  • V E Iacob
  • M Sanchez-Vega
  • R T Effinger
  • P Lipnik
  • V E Mayes
  • D K Willis
  • R G Helmer
چکیده

With the goal of measuring precise gamma-ray intensities for short-lived (< 5 s) accelerator-produced activities, we have calibrated the efficiency of an HPGe detector between 53 and 1836keV to sub-percent precision with a combination of source measurements and Monte Carlo calculations. Using known or independently measured detector dimensions, we have achieved both relative and absolute agreement (the latter, to 0.1%) between the calculated and measured efficiencies with only two adjustable detector parameters, the thicknesses of the contact dead layers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The use of Geant4 for simulations of a plastic β-detector and its application to efficiency calibration

Precise β-branching-ratio measurements are required in order to determine ft-values as part of our program to test the Electroweak Standard Model via unitarity of the Cabibbo-Kobayashi-Moskawa matrix. For the measurements to be useful in this test, their precision must be close to 0.1%. In a branching-ratio measurement, we position the radioactive sample between a thin plastic scintillator used...

متن کامل

Monte Carlo Determination of Full Energy Peak Efficiency for HPGe Detector and Self-Absorption Correction of Environmental Samples

The Monte Carlo method was used to determine full energy efficiency of a high-purity germanium (HPGe) coaxial detector within an energy range of 53.2-2614 keV. Also, measurement was carried out for a standard Marinelli beaker of 600cm3, which was placed into the reference material of mixed gamma. The plot of the experimentally derived effic...

متن کامل

Efficiency determination of HPGe detector by simulation and experimental methods for solid volume source

Analyzes of environmental samples regarding their radioactivity is of important concern for health purposes. We need standard sources to determine radioactive components and their activities. These sources are usually produced regarding type of the sample. One of the fundamental and precise tools to recognize radioactive materials and their activities is HPGe detector. To reach this goal, the d...

متن کامل

Determination of virtual point for HPGe detector at various gamma rays energies by simulation and experimental methods

High Purity Germanium detectors (HPGe) are subdivisions of semiconductor detectors which are widely used in nuclear technology from space industry to nuclear medicine, due to their high resolution, low dead time, unlimited size and compatibility with a variety of environments. The( absolute and intrinsic) efficiency of the HPGe detector, which depends on the geometry of the source-detector syst...

متن کامل

Improving Calibration of HPGe Detectors for In Situ Measurements – a Comparison of Semi-empirical and Monte Carlo Methods

Calibrations of an HPGe detector were made with respect to photon energy and angle of incidence for the use in field gamma spectrometry. The same detector was modelled in MCNP4C and simulated. This revealed some significant differences between the theoretical (simulated) efficiency and the measured efficiency of the detector, especially at lower energies. In order to investigate the reason for ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine

دوره 56 1-2  شماره 

صفحات  -

تاریخ انتشار 2002