Sagittal MR of multiple sclerosis in the spinal cord: fast versus conventional spin-echo imaging.

نویسندگان

  • G J Lycklama à Nijeholt
  • J A Castelijns
  • J Weerts
  • H Adèr
  • J H van Waesberghe
  • C Polman
  • F Barkhof
چکیده

PURPOSE We compared conventional spin-echo (CSE) with fast spin-echo (FSE) dual-echo MR images to determine which of these sequences was better able to depict spinal cord abnormalities in patients with multiple sclerosis (MS). METHODS CSE and FSE dual-echo MR images were obtained in 37 patients with MS and in six healthy control subjects, all of whom were examined on a 1.0-T MR unit with a phased-array coil and cardiac triggering. Two blinded interpreters graded the MR studies, first separately and then by consensus. Images were scored for presence of artifacts, number of focal lesions, and presence of a diffuse increase in signal intensity. RESULTS No abnormalities were seen in the volunteers. The CSE sequences were significantly less hindered by MR imaging artifacts than were the FSE sequences. Interobserver agreement was slightly higher for the CSE than the FSE sequences. After reaching a consensus, the observers found that both CSE and FSE techniques enabled detection of approximately the same number of focal lesions; however, in three patients, small single lesions seen on the CSE images were missed on the FSE images. Also, depiction of a diffuse increase in signal intensity was better on the CSE images. As a result, more patients had abnormal findings on the CSE sequences than on the FSE sequences (35 versus 31). CONCLUSION Cardiac-triggered dual-echo FSE sequences are almost as good as CSE sequences for depicting spinal MS lesions. Therefore, in cases of established spinal MS, FSE techniques may be as effective as CSE techniques. Because sensitivity for subtle abnormalities is lower with FSE imaging, CSE remains the preferred technique for patients with suspected MS of the spinal cord.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Proton Density MRI Increases Detection of Cervical Spinal Cord Multiple Sclerosis Lesions Compared with T2-Weighted Fast Spin-Echo.

BACKGROUND AND PURPOSE There is a paucity of literature that supports the Consortium of Multiple Sclerosis Centers guideline that proton density MR imaging is a core spinal cord sequence. We hypothesized that proton density fast spin-echo imaging is superior to T2 fast spin-echo MR imaging for the detection of cervical cord MS lesions. This study compared the detection rate and conspicuity of c...

متن کامل

The low sensitivity of fluid-attenuated inversion-recovery MR in the detection of multiple sclerosis of the spinal cord.

PURPOSE To confirm the expected superiority of fluid-attenuated inversion-recovery (FLAIR) over conventional fast spin-echo MR imaging in the detection of multiple sclerosis (MS) of the spinal cord. METHODS Fifteen subjects with known MS involving the spinal cord and brain were studied prospectively. The entire cord was imaged with a phased-array coil on a 1.5-T MR system. Sagittal T1-weighte...

متن کامل

Spinal cord lesions in patients with multiple sclerosis: comparison of MR pulse sequences.

PURPOSE To compare T2-weighted conventional spin-echo (CSE), fast spin-echo (FSE), shorttau inversion recovery (STIR) FSE, and fluid-attenuated inversion recovery (FLAIR) FSE sequences in the assessment of cervical multiple sclerosis plaques. METHODS Twenty patients with clinically confirmed multiple sclerosis and signs of cervical cord involvement were examined on a 1.5-T MR system. Sagittal...

متن کامل

Comparison of two MR sequences for the detection of multiple sclerosis lesions in the spinal cord.

PURPOSE To compare cardiac-triggered dual-echo spin-echo and magnetization transfer-prepared gradient-echo (MT-GE) MR imaging in the detection of multiple sclerosis (MS) lesions in the spinal cord. METHODS The cervical spinal cord in 20 patients with MS and in nine healthy volunteers was examined with spin-echo and MT-GE MR imaging. Sagittal images were scored for number of lesions, certainty...

متن کامل

Comparison of MR pulse sequences in the detection of multiple sclerosis lesions.

PURPOSE To compare the sensitivity of conventional spin-echo, fast spin-echo, fast fluid-attenuated inversion recovery (FLAIR), and turbo gradient spin-echo MR sequences in the detection of multiple sclerosis lesions. METHODS Conventional spin-echo, fast spin-echo, fast FLAIR, and turbo gradient spin-echo sequences were performed on a 1.0-T MR imager in seven patients with clinically definite...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 19 2  شماره 

صفحات  -

تاریخ انتشار 1998