Simultaneous determination of organic and cationic species in explosives residues with column-switching liquid chromatography-ion chromatography system.

نویسندگان

  • Peijin Xie
  • Jingang Xu
  • Zhenzhen Hu
  • Fawzi El-Sepai
  • Zhang Peimin
  • Yan Zhu
چکیده

A new column-switching method has been proposed for the determination of 14 organic explosives (1,3,5,7-tetranitro-N-methylaniline, 1,3,5-trinitro-1,3,5-triazacyclohexane, 1,3,5-trinitrobenzene, 1,3-dinitrobenzene, nitrobenzene, 2,4,6-N-tetranitro-N-methylaniline, Trinitrotoluene, 4-amino-2,6-dinitrotoluene, 2-amino-4,6-dinitrotoluene, 2,6-dinitrotoluene, 2,4-dinitrotoluene, 2-nitrotoluene, 4-nitrotoluene, and 3-nitrotoluene) and/or five inorganic cations (Na(+), NH(4)(+), K(+), Mg(2+), and Ca(2+)) using liquid chromatography linked to ion chromatography by a switching valve. The mobile phase was methanol-water (40/60, v/v) for a C18 reversed-phase column and 3 mM of methanesulfonic acid (pH 2.5) for a cation-exchange column, respectively. Under the optimal conditions, the 14 organic explosives and the five inorganic cations were separated and detected simultaneously within 45 min. The limits of detection (S/N = 3) of the 14 organic explosives and the five inorganic cations were in the range of 0.0048-0.0333 mg/L and 0.0116-0.1851 mg/L, respectively. The linear correlation coefficients were 0.9971-0.9999, and the relative standard deviation of the retention time and the peak area were 0.02-0.31% and 0.51-3.64%, respectively. The method was successfully applied to the determination of organic explosives and inorganic cations in dust samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Two Antiepileptic Drugs in Urine by Homogenous Liquid-Liquid Extraction Performed in A Narrow Tube Combined With Dispersive Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection

A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...

متن کامل

Determination of Two Antiepileptic Drugs in Urine by Homogenous Liquid-Liquid Extraction Performed in A Narrow Tube Combined With Dispersive Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection

A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...

متن کامل

Column Switching and Liquid Chromatographic Technique for the Rapid Determination of Fenoxycarb Insecticide Residues in Apples

Fenoxycarb residues are analyzed by column switching and reversed-phase high performance liquid chromatography (RP-HPLC). The active ingredient is extracted from apples on a silica gel column using a n-hexane diethyl ether mixture. The eluate is evaporated, dry residue dissolved in acetonitrile-deionized water, and injected into the liquid chromatograph with a column switching system (C8 column...

متن کامل

High Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat

Glutathione (GSH) is one of the most important antioxidants that plays an essential role in detoxification of reactive oxygen species (ROS) which oxidizes to glutathione disulfide (GSSG). Paraquat (PQ), awidely used herbicide, causes pulmonary injury with the productionof ROS. Excessive ROS accumulation as a consequence of PQ exposure are frequently targeted by GSH thereby oxidative stress lead...

متن کامل

High Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat

Glutathione (GSH) is one of the most important antioxidants that plays an essential role in detoxification of reactive oxygen species (ROS) which oxidizes to glutathione disulfide (GSSG). Paraquat (PQ), awidely used herbicide, causes pulmonary injury with the productionof ROS. Excessive ROS accumulation as a consequence of PQ exposure are frequently targeted by GSH thereby oxidative stress lead...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatographic science

دوره 49 8  شماره 

صفحات  -

تاریخ انتشار 2011