Rotating Scans for Systematic Error Removal

نویسندگان

  • Fatemeh Abbasinejad
  • Yong Joo Kil
  • Andrei Sharf
  • Nina Amenta
چکیده

Optical triangulation laser scanners produce errors at surface discontinuities and sharp features. These systematic errors are anisotropic. We examine the causes of these errors theoretically, and we study the correlation of systematic error with edge size and orientation experimentally. We then present a novel processing method for removing systematic errors, by combining scans taken at several different orientations. We apply an anisotropic filter to the separate scans, and use it to weight the data in a final combination step. Unlike previous approaches, our method does not require access to the scanner’s internal data or firmware. We demonstrate the technique on data from laser range scanners by two different manufacturers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On-Site Sensor Recalibration of a Spinning Multi-Beam LiDAR System Using Automatically-Detected Planar Targets

This paper presents a fully-automated method to establish a calibration dataset from on-site scans and recalibrate the intrinsic parameters of a spinning multi-beam 3-D scanner. The proposed method has been tested on a Velodyne HDL-64E S2 LiDAR system, which contains 64 rotating laser rangefinders. By time series analysis, we found that the collected range data have random measurement errors of...

متن کامل

CO2 Removal from Air in a Countercurrent Rotating Packed Bed, Experimental Determination of Height of Transfer Unit

Carbon dioxide capture is a key issue in climate change mitigation. For decades the removal of carbon dioxide has been an essential step in many industrial processing operations such as the synthesis of ammonia, natural gas purification, and oil refining. In this study, a rotating packed bed has been designed for absorption of carbon dioxide from an air stream. The rotating packed bed is a comp...

متن کامل

Dairy Wastewater Treatment using Three-Stage Rotating Biological Contactor (NRBC)

Dairy wastewater is enriched in organic matter (about 45-72 g/l, COD) and also contains biodegradable carbohydrates. A three-stage system, NRBC was fabricated as a bench scale unit for lab experiments, to remove organic carbon from the whey. The fabricated NRBC had several advantages, such as quick start-up, high biomass concentration and was additionally able to handle high organic loading rat...

متن کامل

Uncertainty of Line Segments Extracted from Static SICK PLS Laser Scans A. Diosi and L. Kleeman Uncertainty of Line Segments Extracted from Static SICK PLS Laser Scans

Data fusion using Kalman filters requires reasonably good error models. Our intention to fuse line segments, corners and edges obtained from a laser scanner and from advanced sonars provided the motivation on the investigation of Sick PLS laser scanner range measurement reliability, and line segment estimation precision. We present an approach for fitting lines straight in the lasers polar coor...

متن کامل

Physico-Chemical and Biological Treatment of Olive Mill Wastewater by Rotating Biological Contactor (RBC) Reactors

The removal performance of total poly phenols and orthodiphenols (o-diphenols) content in olive mill waste (OMW) was investigated with a three stages cross flow laboratory scale rotating biological contactor (RBC) in the present study. Due to high COD and other pollutant in the original OMW, physico-chemical treatment was effected for COD and other pollutant reduction prior to biological tr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Comput. Graph. Forum

دوره 28  شماره 

صفحات  -

تاریخ انتشار 2009