Control system renewal for efficient operation in RIKEN 18 GHz electron cyclotron resonance ion source.

نویسندگان

  • A Uchiyama
  • K Ozeki
  • Y Higurashi
  • M Kidera
  • M Komiyama
  • T Nakagawa
چکیده

A RIKEN 18 GHz electron cyclotron resonance ion source (18 GHz ECRIS) is used as an external ion source at the Radioactive Ion Beam Factory (RIBF) accelerator complex to produce an intense beam of medium-mass heavy ions (e.g., Ca and Ar). In most components that comprise the RIBF, the control systems (CSs) are integrated by the Experimental Physics and Industrial Control System (EPICS). On the other hand, a non-EPICS-based system has hardwired controllers, and it is used in the 18 GHz ECRIS CS as an independent system. In terms of efficient and effective operation, the 18 GHz ECRIS CS as well as the RIBF CS should be renewed using EPICS. Therefore, we constructed an 18 GHz ECRIS CS by using programmable logic controllers with embedded EPICS technology. In the renewed system, an operational log system was developed as a new feature, for supporting of the 18 GHz ECRIS operation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time Evolution of Plasma Potential in Pulsed Operation of Ecris*

The time evolution of plasma potential has been measured with a retarding field analyzer in pulsed operation mode with electron cyclotron resonance ion sources at JYFL and RIKEN. Three different ion sources with microwave frequencies ranging from 6.4 to 18 GHz were employed for the experiments. The plasma potential was observed to increase 10-75 % during the preglow and 10-30 % during the after...

متن کامل

Venus: the next Generation Ecr Ion Source

The construction of VENUS, an Electron Cyclotron Resonance ion source designed to operate at 28 GHz, is nearing completion. Tests with the superconducting magnet assembly produced axial magnetic field strengths of 4 T at injection and 3 T at extraction and a sextupole field of 2 T at the plasma wall. These fields are sufficient for optimum operation at 28 GHz. We expect a shift to higher charge...

متن کامل

Electron-beam extraction system for the Frankfurt 14 GHz electron cyclotron resonance ion source

A new concept to assist in the extraction of ion beams from an electron cyclotron resonance ion source ~ECRIS! by the injection of an electron beam from the extraction side into the ion-source plasma is proposed. In this article, the construction of a test setup is described and first results of experiments with this setup at the 14 GHz ECRIS of the Frankfurt ECRIS-~ve!RFQ facility are reported...

متن کامل

Cusped Mirror Magnetic Field for Electron Cyclotron Resonance Heavy Ion Source

Sufficient beams of Highly Charged Heavy Ions (HCHI) have been obtained in conventional electron cyclotron resonance ion sources (ECRIS) but at the cost of simplicity and economy. A cusped magnetic field (CMF) has more plasma-confining feature but a little current of HCHI’s was extracted from ECRIS using it. The CMF has been reconfigured adopting a simple, novel and cost-effective technique. It...

متن کامل

Plasma diagnostics at electron cyclotron resonance ion sources by injection of laser ablated fluxes of metal atoms

Short pulses of neutral particles generated by laser ablation of metal targets have been injected into the Frankfurt 14 GHz electron cyclotron resonance ~ECR! ion source. Rise/fall times of pulses of highly charged ions of Cd and Mg were registered as a function of microwave power and gas pressure. From a comparison of the measured data to numerical simulations, values of the electron density a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 87 2  شماره 

صفحات  -

تاریخ انتشار 2016