Determination of aluminium-26 in biological materials by accelerator mass spectrometry.

نویسندگان

  • S J King
  • C Oldham
  • J F Popplewell
  • R S Carling
  • J P Day
  • L K Fifield
  • R G Cresswell
  • K Liu
  • M L di Tada
چکیده

Studies of the biological chemistry of aluminium can gain significantly from the use of the long-lived isotope 26Al as a tracer, although the cost of the isotope often precludes its determination by radiochemical counting techniques. Accelerator mass spectrometry (AMS) provides an ultra-sensitive method of determination, free from isobaric interference from atomic (26Mg) or molecular species. The source materials for AMS can be aluminium oxide or phosphate, both of which can be readily prepared at a sufficient level of purity from biological substrates. Natural aluminium (27Al, 100%) is added to the preparations as a chemical yield monitor and to provide the reference for the isotope ratio measurement. 26Al/27Al ratios can be determined over the range 10(-14)-10(-7), implying a limit of detection for 26Al of around 10(-18) g. The precision of measurement and long-term reproducibility are < 5% and < 7% (RSD), respectively. Chemical methodologies for routine measurements on blood and urine samples have been developed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The biological behaviour and bioavailability of aluminium in man, with special reference to studies employing aluminium-26 as a tracer: review and study update.

Until 1990 biokinetic studies of aluminium metabolism and biokinetics in man and other animals had been substantially inhibited by analytical and practical difficulties. Of these, the most important are the difficulties in differentiating between administered aluminium and endogenous aluminium-especially in body fluids and excreta and the problems associated with the contamination of samples wi...

متن کامل

Intestinal absorption of trace amounts of aluminium in rats studied with 26aluminium and accelerator mass spectrometry.

1. Until recently studies of intestinal aluminium absorption used pharmacological amounts of stable 27Al. 2. To examine the intestinal absorption of trace amounts of different chemical compounds of aluminium, in the present study we have employed the long half-life isotope of aluminium, 26Al, and accelerator mass spectrometry. Trace amounts of 26Al (2.7-12.1 ng) as the hydroxide, citrate, citra...

متن کامل

Relative Determination Approach to the Metabolites of Protoberberine Alkaloids in Rat Urine by Liquid Chromatography Tandem Mass Spectrometry for the Comparative Studies on Rhizome coptidis and Zuojinwan Preparation

The lack of authentic standards has limited the quantitative analysis of herbal drugs in biological samples. The present work demonstrated a practicable strategy for the assay of herbs and their metabolites independent of authentic standards. A liquid chromatography–electrospray ionization–mass spectrometry (LC–ESI–MS) method for the qualitative and quantitative determination of the metabolites...

متن کامل

Relative Determination Approach to the Metabolites of Protoberberine Alkaloids in Rat Urine by Liquid Chromatography Tandem Mass Spectrometry for the Comparative Studies on Rhizome coptidis and Zuojinwan Preparation

The lack of authentic standards has limited the quantitative analysis of herbal drugs in biological samples. The present work demonstrated a practicable strategy for the assay of herbs and their metabolites independent of authentic standards. A liquid chromatography–electrospray ionization–mass spectrometry (LC–ESI–MS) method for the qualitative and quantitative determination of the metabolites...

متن کامل

Potential of Liquid Chromatography–Atmospheric Pressure Chemical Ionisation Tandem Mass Spectrometry for Determination of Fosetyl-aluminium Residues in Dried Hops

P������ J., H������� J., H������� K., N������� K. (2004): Potential of liquid chromatography–atmospheric pressure chemical ionisation tandem mass spectrometry for determination of fosetyl-aluminium residues in dried hops. Czech J. Food Sci., 22: 24–28. New analytical procedure for the determination of fosetyl-aluminium in hop cones (also called “hops”) was developed. Liquid chromatography–atmos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 122 10  شماره 

صفحات  -

تاریخ انتشار 1997