Surface myoelectric signal cross-talk among muscles of the leg.

نویسندگان

  • C J De Luca
  • R Merletti
چکیده

Surface myoelectric signals were detected from the skin surface above the tibialis anterior muscle, the peroneus brevis muscle, the soleus muscle and the tibial bone during selective maximal electrical stimulation of the tibialis anterior muscle in 12 normal subjects. The double differential technique developed by Broman et al. (1985) was used to determine if the detected signal was due to volume conduction from the tibialis anterior fibers. The peak-to-peak (PP), average rectified (ARV) and root mean square (RMS) amplitudes of the M waves were computed for each detection location. The values detected on the tibial bone, on the peroneus and on the soleus muscles were normalized with respect to those detected on the tibialis anterior and ranged from 4.8% to 33.0% (PP), 4.7% to 36.0% (ARV), and 7.7% to 37.4% (RMS) for the tibial bone area; from 4.0% to 20.0% (PP), 3.5% to 10.0% (ARV), and 3.0% to 10.0% (RMS) for the peroneus brevis muscle area; and from 3.0% to 8.0% (PP), 3.4% to 9.1% (ARV), and 2.0% to 9.8% (RMS) for the soleus muscle area. Neither peak-to-peak values, average rectified values nor root mean square values appeared to be correlated with leg size. It is concluded that a surface myoelectric signal detected on the skin above a leg muscle and having a peak-to-peak amplitude of up to 16.6% of a signal detected above a neighboring muscle may be due to cross-talk rather than to activation of the muscle below the electrode.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Removing ECG Artifact from the Surface EMG Signal Using Adaptive Subtraction Technique

Background: The electrocardiogram artifact is a major contamination in the electromyogram signals when electromyogram signal is recorded from upper trunk muscles and because of that the contaminated electromyogram is not useful.Objective: Removing electrocardiogram contamination from electromyogram signals.Methods: In this paper, the clean electromyogram signal, electrocardiogram artifact and e...

متن کامل

Advanced Signal Processing Techniques Applied to Cross-talk Reduction in Forearm S-emg

In spite of the great advances in the mechanical and electronic components of prosthetic hands, they still lack the high number of degrees of freedom present in the real human hand. That is due, not to technical deficiencies, but to the much reduced amount of independent control signals available when using surface electromyography (s-EMG) from the forearm stump or other artificial sensors. Cro...

متن کامل

The effect of subcutaneous fat on myoelectric signal amplitude and cross-talk.

The effect of subcutaneous fat on myoelectric signal amplitude and cross-talk was studied using finite element (FE) models of electromyogram (EMG) signal propagation. A FE model of the upper arm consisted of skin, fat, muscle and bone tissues in concentric layers. Single muscle fibre action potentials were simulated for muscle fibres at a variety of depths and combined to simulate surface EMG i...

متن کامل

Spectral properties of myoelectric signals from different motor units in the leg extensor muscles.

Myoelectric signals measured using intramuscular electromyograms (EMGs) in animals have shown that faster motor units generate higher frequencies in their power spectra. However, evidence to relate myoelectric frequency and motor unit type from the surface electromyograms typically measured from man have remained elusive. The purpose of this study was to determine if spectral properties from su...

متن کامل

Implantable Myoelectric Sensors (IMES)

We are developing a multi-channel/multifunction prosthetic hand/arm controller system capable of receiving and processing signals from up to sixteen Implanted MyoElectric Sensors (IMES). The appeal of implanted sensors for myoelectric control is that EMG signals can be measured at their source providing relatively cross-talk free signals that can be treated as independent control sites. Therefo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Electroencephalography and clinical neurophysiology

دوره 69 6  شماره 

صفحات  -

تاریخ انتشار 1988