Aortic Remodeling Following Sun’s Procedure for Acute Type A Aortic Dissection

نویسندگان

  • Jiawen Luo
  • Xianming Fu
  • Yangzhao Zhou
  • Hao Tang
  • Guobao Song
  • Tao Tang
  • Xiaobo Liao
  • Xinmin Zhou
چکیده

BACKGROUND Sun's procedure is a surgical technique widely used in type A aortic dissection. The purpose of this study was to analyze clinical outcomes and morphologic changes in true and false lumen by computed tomography (CT) angiography after Sun's procedure. MATERIAL AND METHODS We retrospectively reviewed 51 patients who underwent Sun's procedure for acute Stanford type A aortic dissection extending down to iliac bifurcation between January 2013 and December 2014. The images of preoperative, one-month, three-month, and six-month follow-up were analyzed by CT angiography to measure the area and diameter of true and false lumen. RESULTS Four patients died before surgical intervention and postoperative deaths occurred in five patients (in-hospital mortality rate 10.6%). Only 42 patients (36 male, 6 female; mean age, 45.9±9.8 years; range, 24-65 years) with acute type A aortic dissection were involved in our study. Thirty-five patients (83.3%) suffered from chest or abdominal pain and only one patient (2.4%) was asymptomatic. Thirty-seven patients (88.1%) had hypertension as the most common comorbidity. In the ascending aorta, false lumen was eliminated and the change of true lumen was not significant (p>0.05). In the descending aorta, complete and partial thrombosis of false lumen were observed in eight patients (19.0%) and 33 patients (78.6%) by one-month follow-up CT scan, respectively. After the six-month follow-up, the rate of complete thrombosis increased to 36.1% and partial thrombosis decreased to 61.9%. The area and maximal diameter of true lumen were increased significantly (p<0.05), whereas significant decreases were found in the area and maximal diameter of false lumen (p<0.05). In the abdominal aorta, thrombosis was found in 52.4% patients at one-month follow-up CT. Furthermore, there were no significant changes in both true and false lumen within three months (p>0.05). Nevertheless, the false luminal area and maximal diameter decreased significantly (p<0.05) after six months, while these changes of true lumen were not significant (p>0.05). CONCLUSIONS After Sun's procedure, aortic remodeling was a continuous process and occurred in a predictable model, and the extent of aortic remodeling varied at different levels. Remodeling in descending thoracic aorta was earlier than it was in abdominal aorta.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acute Type A Dissection and Acute Inferior MI Complicating Aortic Coarctation: A Case Report

Aortic coarctation is a rare but dangerous condition. Presence of aortic dissection in addition to coarctation is significantly rarer and more life-threatening. Here, we present a case of acute inferior MI due to aortic dissection complicating a native aortic coarctation. A 17-year-old boy was admitted to our emergency department due to severe chest pain and loss of consciousness. His ele...

متن کامل

Aortic Pseudo aneurysm 3 Years after Interposition Tube Graft for Acute Dissection of Ascending Aorta

Introduction: Patients with primary acute aortic dissection are at higher risk of complications, including increasing aortic aneurysm diameter, aortic rupture, aortic pseudo aneurysm, and recurrent aortic dissection. Case presentation We presented the case of a recurrent pseudo aneurysm and rupture of the aorta in the distal a...

متن کامل

Successful Repair of Type a Aortic Dissection in a Term Pregnancy: A Case Report

Stanford type A acute aortic dissection (AAD) is a very rare complication, with potentially lethal consequences in pregnancy. In fact, pregnancy has been regularly associated with the possibility of aortic. dissection in almost half of young women. Herein, we present the case of a 38-year-old woman in her 37th week of pregnancy. The patient’s medical history was indicative of G4L2Ab1(4 gestaiti...

متن کامل

گزارش شش مورد دیسکسیون حاد آئورت با علائم غیر معمولی

Acute aortic dissection is a common disease caused by primary tear in the aortic intima or rupture of vasa vasorum. Every year 5-30 per million are affected by that. Untreated aortic dissection (dissecting aortic aneurysm) carries a high mortality rate. More than 90% of acute dissections present with acute pain in chest or back or both. Aortic dissection may mimic other more common conditions...

متن کامل

Sun's procedure for chronic type A aortic dissection: total arch replacement using a tetrafurcate graft with stented elephant trunk implantation.

The Sun’s procedure is a surgical technique that integrates total arch replacement using a tetrafurcated graft with implantation of a special stented graft in the descending aorta, as a treatment option for extensive dissections or aneurysms involving the ascending aorta, aortic arch and descending aorta (1-3). To illustrate our technique for performing the Sun’s procedure (1,2), we present a v...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 23  شماره 

صفحات  -

تاریخ انتشار 2017