Port-Site Closure: A New Problem, An Old Device

نویسندگان

  • Nicola Di Lorenzo
  • Giorgio Coscarella
  • Francesca Lirosi
  • Achille Gaspari
چکیده

OBJECTIVE Trocar-site incisional hernias and their complications are reported in 1% to 6% of patients. Such hernias are attributed to the difficulty of applying standard suturing techniques to wound closure. We report our experience with a simple device, the Deschamps ligature needle. METHODS The Deschamps needle has a handle and a tip (sharp or blunt), with an opening to pass suture. The blunt tip is very effective for closing trocar sites. Disposable needles are obviously sharp, but can bend on the needle holder and break in a deep small incision. The Deschamps needle is a rigid, noncutting instrument that can be forced through fascia and peritoneum (around the surgeon's fingertip) avoiding loss of pneumoperitoneum. A full-thickness closure is accomplished. We perform closure under direct vision through the scope. Tactile sense is provided by the surgeon's finger. The last trocar site is closed in the same manner without the scope. RESULTS We have used the Deschamps needle since 1992 in all (1400) laparoscopic procedures. We close 10-mm and 5-mm trocar sites and have not observed wound dehiscence or hernias at these sites. CONCLUSION The Deschamps needle is effective in preventing incisional hernias and wound dehiscence. It is cost-effective. Disposable, single-use devices vary in price from $30 to $75 each. The Deschamps needle is sold in Italy at approximately $35 each. Considering that it may have been in the trays of most operating rooms for years (as in our case), and the number of procedures performed, we conclude that the real cost of this instrument is almost negligible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laparoscopic Cholecystectomy; closure versus non-closure of the fascial sheath opening of the sub-umbilical port site “10 mm”.

Background: Laparoscopic Surgery (LS) may be associated with many port site complications such as hernia, bleeding, infection, subcutaneous emphysema and ugly scars. Some of these complications are serious such as obstructed port site hernia . Rate of these complications is low depending  on size and site of the port incision, type of the trocar that it is used, the condition of  the patient a...

متن کامل

متاستاز کانسر کیسه صفرا به محل هر چهار پورت پس از انجام کوله سیستکتومی لاپاروسکوپیک: گزارش موردی

Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal" mso-tstyle-rowband-size:0 mso-tstyle-colband-size:0 mso-style-noshow:yes mso-style-priority:99 mso-style-qformat:yes m...

متن کامل

Effective, simple, easy procedure for laparoscopic port closure in difficult cases

BACKGROUND Laparoscopic and rebotic surgery is widely practiced in modern medicine. The operative procedure is not complete until the port sites are closed with a fascial closure. Good fascial closure still represents problem, especially in difficult obese patients. This study reported simple technique is suitable in such cases. MATERIAL AND METHODS We herein describe a simple technique for f...

متن کامل

Long-Term Study of Port-Site Incisional Hernia After Laparoscopic Procedures

BACKGROUND Laparoscopic surgery is widely practiced and offers realistic benefits over conventional surgery. There is considerable variation in results between surgeons, concerning port-site complications. The aim of this study was to evaluate the laparoscopic port closure technique and to explore the factors associated with port-site incisional hernia. METHODS Between January 2000 and Januar...

متن کامل

Trocar site hernia on an 8-mm port following robotic-assisted hysterectomy.

The increasing use of laparoscopy has resulted in added complications specific to the laparoscopic approach, such as trocar site hernia (TSH), which is an uncommon but well-recognized problem for both regular laparoscopic and robotic-assisted laparoscopic procedures. We describe an extremely rare case of TSH at an 8-mm port site occurring a relatively short time after surgery in a 53-year-old p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2002