Reliability of the Pettibon Patient Positioning System for Radiographic Production
نویسنده
چکیده
The research reported here investigated the reliability of the patient positioning procedure used to evaluate the upper cervical region by practitioners of the Pettibon Technique and sought to establish the range of error of measurement for mensuration. Thirty-eight subjects completed the study which included taking two series of both an anterior to posterior nasium as well as lateral cervical radiographs. The second series of x-rays were taken from one-half to 4 hours after the initial radiographs.While there were no intermediate chiropractic adjustments provided, the use of a simulated adjustment was performed.The collected data indicates that the reliability, as represented by the standard error measurement, is approximately one-half a degree for the upper angle measurement and two-thirds of a degree for the lower angle measurement. In both cases, the measurement error estimate is less than the one degree claimed by the author of the method tested.
منابع مشابه
Calculation and Analysis of Reliability with Consideration of Common Cause Failures (CCF) (Case Study: The Input of the Dynamic Positioning System of a Submarine)
Abstract The reliability and safety of any system is the most important qualitative characteristic of a system. This qualitative characteristic is of particular importance in systems whose functions are under various stresses, such as high temperature, high speed, high pressure, etc. A considerable point, which is rarely taken into account when calculating the reliability and safety of syst...
متن کاملAdolescent IdiopathicScoliosisTreatment UsingPettibonCorrectiveProcedures: ACaseReport
Objective: To investigate the possible benefits of using Pettibon corrective procedures to reduce the curvature associated with idiopathic scoliosis. These procedures were tested to determine potential effectiveness in a single patient. Clinical Features: A patient with a 35° left convex thoracolumbar scoliosis was treated using Pettibon corrective procedures. Initial and follow-up outcome meas...
متن کاملAdolescent idiopathic scoliosis treatment using the Pettibon corrective procedures: a case report.
Adolescent idiopathic scoliosis treatment using the Pettibon corrective procedures: a case report To the Editor: This is an update to a previously published study. We previously reported on a 20-year-old female patient with a 358 thoracolumbar levoscoliosis. 1 Her results after 6 weeks of Pettibon treatment were reported. However, the patient was dismissed from active care and relocated out of ...
متن کاملGPS Time Reception Using Altera SOPC Builder and Nios II: Application in Train Positioning
As functional integration has increased in hand-held consumer devices features such as Global Positioning System (GPS) receivers have been embedded in increasingly more devices in recent years. For example, the train positioning system based on GPS provides an integrated positioning solution which can be used in many rail applications without a cost intensive infrastructure. The network built i...
متن کاملGravity Reduction View: A Radiographic Technique for the Evaluation and Management of Weber B Fibula Fractures
Background: While various radiographic parameters and application of manual/gravity stress have been proposed to elucidate instability for Weber B fibula fractures, the prognostic capability of these modalities remains unclear. Determination of anatomic positioning of the mortise is paramount. We propose a novel view, the Gravity Reduction View (GRV), which helps elucidate non-anatomic position...
متن کامل